SIMULTANEOUS COPRECIPITATION OF PD(II), RH(III) AND AU(III) WITH MN(OH)2 WITHOUT CHELATING AGENT PRIOR TO FLAME ATOMIC ABSORPTION SPECTROMETRY DETERMINATION

A separation-preconcentration procedure was developed for determination of trace amounts of palladium, rhodium and gold in dust and water samples by flame atomic absorption spectrometry after simultaneous coprecipitation by Mn(OH)2 without chelating agent. The precipitate could be easily dissolved w...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: MOHAMMADI,S.Z, KARIMI,M.A, HAMIDIAN,H, BAGHELANI,Y.M, KARIMZADEH,L
Lenguaje:English
Publicado: Sociedad Chilena de Química 2012
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000100011
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072012000100011
record_format dspace
spelling oai:scielo:S0717-970720120001000112012-07-19SIMULTANEOUS COPRECIPITATION OF PD(II), RH(III) AND AU(III) WITH MN(OH)2 WITHOUT CHELATING AGENT PRIOR TO FLAME ATOMIC ABSORPTION SPECTROMETRY DETERMINATIONMOHAMMADI,S.ZKARIMI,M.AHAMIDIAN,HBAGHELANI,Y.MKARIMZADEH,L Palladium Rhodium Gold Coprecipitation Preconcentration FAAS Road dust and water samples A separation-preconcentration procedure was developed for determination of trace amounts of palladium, rhodium and gold in dust and water samples by flame atomic absorption spectrometry after simultaneous coprecipitation by Mn(OH)2 without chelating agent. The precipitate could be easily dissolved with concentrated nitric acid. The influence of the various analytical parameters such as pH, sample volume, centrifuge time, standing time, centrifugation rate and time, amounts of manganese and matrix effects were studied for the quantitative recoveries of the analyte ions. Under the optimized experimental conditions, the calibration curves for Pd(II), Rh(III) and Au(III) were linear from 8.0 to 2000.0, 1.0 to 750.0 and 5.0 to 1000.0 ng mL-1, respectively. The relative standard deviations for seven replicate determinations of a mixture of 0.1 mg mL-1 palladium, rhodium and gold in the original solution were 2.1, 1.9 and 2.4%, respectively. The detection limits based on 3Sb for Pd(II), Rh(III) and Au(III) in the original solution were 2.2, 0.3 and 1.3 ng mL-1, respectively. The proposed method has been applied for determination of trace amounts of palladium, rhodium and gold ions in the standard, road dust and water samples and satisfactory results were obtained.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.57 n.1 20122012-03-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000100011en10.4067/S0717-97072012000100011
institution Scielo Chile
collection Scielo Chile
language English
topic Palladium
Rhodium
Gold
Coprecipitation
Preconcentration
FAAS
Road dust and water samples
spellingShingle Palladium
Rhodium
Gold
Coprecipitation
Preconcentration
FAAS
Road dust and water samples
MOHAMMADI,S.Z
KARIMI,M.A
HAMIDIAN,H
BAGHELANI,Y.M
KARIMZADEH,L
SIMULTANEOUS COPRECIPITATION OF PD(II), RH(III) AND AU(III) WITH MN(OH)2 WITHOUT CHELATING AGENT PRIOR TO FLAME ATOMIC ABSORPTION SPECTROMETRY DETERMINATION
description A separation-preconcentration procedure was developed for determination of trace amounts of palladium, rhodium and gold in dust and water samples by flame atomic absorption spectrometry after simultaneous coprecipitation by Mn(OH)2 without chelating agent. The precipitate could be easily dissolved with concentrated nitric acid. The influence of the various analytical parameters such as pH, sample volume, centrifuge time, standing time, centrifugation rate and time, amounts of manganese and matrix effects were studied for the quantitative recoveries of the analyte ions. Under the optimized experimental conditions, the calibration curves for Pd(II), Rh(III) and Au(III) were linear from 8.0 to 2000.0, 1.0 to 750.0 and 5.0 to 1000.0 ng mL-1, respectively. The relative standard deviations for seven replicate determinations of a mixture of 0.1 mg mL-1 palladium, rhodium and gold in the original solution were 2.1, 1.9 and 2.4%, respectively. The detection limits based on 3Sb for Pd(II), Rh(III) and Au(III) in the original solution were 2.2, 0.3 and 1.3 ng mL-1, respectively. The proposed method has been applied for determination of trace amounts of palladium, rhodium and gold ions in the standard, road dust and water samples and satisfactory results were obtained.
author MOHAMMADI,S.Z
KARIMI,M.A
HAMIDIAN,H
BAGHELANI,Y.M
KARIMZADEH,L
author_facet MOHAMMADI,S.Z
KARIMI,M.A
HAMIDIAN,H
BAGHELANI,Y.M
KARIMZADEH,L
author_sort MOHAMMADI,S.Z
title SIMULTANEOUS COPRECIPITATION OF PD(II), RH(III) AND AU(III) WITH MN(OH)2 WITHOUT CHELATING AGENT PRIOR TO FLAME ATOMIC ABSORPTION SPECTROMETRY DETERMINATION
title_short SIMULTANEOUS COPRECIPITATION OF PD(II), RH(III) AND AU(III) WITH MN(OH)2 WITHOUT CHELATING AGENT PRIOR TO FLAME ATOMIC ABSORPTION SPECTROMETRY DETERMINATION
title_full SIMULTANEOUS COPRECIPITATION OF PD(II), RH(III) AND AU(III) WITH MN(OH)2 WITHOUT CHELATING AGENT PRIOR TO FLAME ATOMIC ABSORPTION SPECTROMETRY DETERMINATION
title_fullStr SIMULTANEOUS COPRECIPITATION OF PD(II), RH(III) AND AU(III) WITH MN(OH)2 WITHOUT CHELATING AGENT PRIOR TO FLAME ATOMIC ABSORPTION SPECTROMETRY DETERMINATION
title_full_unstemmed SIMULTANEOUS COPRECIPITATION OF PD(II), RH(III) AND AU(III) WITH MN(OH)2 WITHOUT CHELATING AGENT PRIOR TO FLAME ATOMIC ABSORPTION SPECTROMETRY DETERMINATION
title_sort simultaneous coprecipitation of pd(ii), rh(iii) and au(iii) with mn(oh)2 without chelating agent prior to flame atomic absorption spectrometry determination
publisher Sociedad Chilena de Química
publishDate 2012
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000100011
work_keys_str_mv AT mohammadisz simultaneouscoprecipitationofpdiirhiiiandauiiiwithmnoh2withoutchelatingagentpriortoflameatomicabsorptionspectrometrydetermination
AT karimima simultaneouscoprecipitationofpdiirhiiiandauiiiwithmnoh2withoutchelatingagentpriortoflameatomicabsorptionspectrometrydetermination
AT hamidianh simultaneouscoprecipitationofpdiirhiiiandauiiiwithmnoh2withoutchelatingagentpriortoflameatomicabsorptionspectrometrydetermination
AT baghelaniym simultaneouscoprecipitationofpdiirhiiiandauiiiwithmnoh2withoutchelatingagentpriortoflameatomicabsorptionspectrometrydetermination
AT karimzadehl simultaneouscoprecipitationofpdiirhiiiandauiiiwithmnoh2withoutchelatingagentpriortoflameatomicabsorptionspectrometrydetermination
_version_ 1718445460216086528