USING AN INDOL DERIVATIVE AS COMPLEXING AGENT FOR CLOUD POINT PRECONCENTRATION AND DETERMINATION OF MAGNESIUM AND SILVER IONS IN VARIOUS SAMPLES BY FAAS

A very simple cloud point extraction (CPE) methodology for the preconcentration of trace amounts of silver and magnesium as a prior step for their determination by flame atomic absorption spectrometry (FAAS) has been developed. The method is based on the extraction of silver and magnesium at pH 10 b...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: SHOKROLLAHI,ARDESHIR, TAVALLALI,HOSSEIN, MONTASERI,ZOHREH, NIKNAM,KHODABAKHSH
Lenguaje:English
Publicado: Sociedad Chilena de Química 2012
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000200017
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072012000200017
record_format dspace
spelling oai:scielo:S0717-970720120002000172014-03-10USING AN INDOL DERIVATIVE AS COMPLEXING AGENT FOR CLOUD POINT PRECONCENTRATION AND DETERMINATION OF MAGNESIUM AND SILVER IONS IN VARIOUS SAMPLES BY FAASSHOKROLLAHI,ARDESHIRTAVALLALI,HOSSEINMONTASERI,ZOHREHNIKNAM,KHODABAKHSH Silver Magnesium Cloud-point extraction Flame atomic absorption A very simple cloud point extraction (CPE) methodology for the preconcentration of trace amounts of silver and magnesium as a prior step for their determination by flame atomic absorption spectrometry (FAAS) has been developed. The method is based on the extraction of silver and magnesium at pH 10 by using non-ionic surfactant Triton X-114 and 4 methyl-3-((1-H-Indol-3-iyl) (phenyl) methyl)) -1-H-Indol (MPBIM) as a complexing agent. Several important variables that affect the CPE efficiency and FAAS signal were investigated and optimized. The calibration curves, using the preconcentration system, were linear in the range of 0.007-0.200 μg mL-1 with a correlation coefficient of 0.999. The lower limits of detection (3s) obtained in the optimal conditions were 1.47 ng mL-1 and 3.00 ng mL-1 for Mg²+ and Ag+ ions, respectively. The relative standard deviation for five replicate determinations of magnesium and silver at 0.133 μg mL-1 concentration level, were 1.17 and 0.97, respectively. The proposed method was successfully applied to the ultra-trace determination of silver and magnesium in various water samples, blood serum, urine, and radiology film samples.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.57 n.2 20122012-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000200017en10.4067/S0717-97072012000200017
institution Scielo Chile
collection Scielo Chile
language English
topic Silver
Magnesium
Cloud-point extraction
Flame atomic absorption
spellingShingle Silver
Magnesium
Cloud-point extraction
Flame atomic absorption
SHOKROLLAHI,ARDESHIR
TAVALLALI,HOSSEIN
MONTASERI,ZOHREH
NIKNAM,KHODABAKHSH
USING AN INDOL DERIVATIVE AS COMPLEXING AGENT FOR CLOUD POINT PRECONCENTRATION AND DETERMINATION OF MAGNESIUM AND SILVER IONS IN VARIOUS SAMPLES BY FAAS
description A very simple cloud point extraction (CPE) methodology for the preconcentration of trace amounts of silver and magnesium as a prior step for their determination by flame atomic absorption spectrometry (FAAS) has been developed. The method is based on the extraction of silver and magnesium at pH 10 by using non-ionic surfactant Triton X-114 and 4 methyl-3-((1-H-Indol-3-iyl) (phenyl) methyl)) -1-H-Indol (MPBIM) as a complexing agent. Several important variables that affect the CPE efficiency and FAAS signal were investigated and optimized. The calibration curves, using the preconcentration system, were linear in the range of 0.007-0.200 μg mL-1 with a correlation coefficient of 0.999. The lower limits of detection (3s) obtained in the optimal conditions were 1.47 ng mL-1 and 3.00 ng mL-1 for Mg²+ and Ag+ ions, respectively. The relative standard deviation for five replicate determinations of magnesium and silver at 0.133 μg mL-1 concentration level, were 1.17 and 0.97, respectively. The proposed method was successfully applied to the ultra-trace determination of silver and magnesium in various water samples, blood serum, urine, and radiology film samples.
author SHOKROLLAHI,ARDESHIR
TAVALLALI,HOSSEIN
MONTASERI,ZOHREH
NIKNAM,KHODABAKHSH
author_facet SHOKROLLAHI,ARDESHIR
TAVALLALI,HOSSEIN
MONTASERI,ZOHREH
NIKNAM,KHODABAKHSH
author_sort SHOKROLLAHI,ARDESHIR
title USING AN INDOL DERIVATIVE AS COMPLEXING AGENT FOR CLOUD POINT PRECONCENTRATION AND DETERMINATION OF MAGNESIUM AND SILVER IONS IN VARIOUS SAMPLES BY FAAS
title_short USING AN INDOL DERIVATIVE AS COMPLEXING AGENT FOR CLOUD POINT PRECONCENTRATION AND DETERMINATION OF MAGNESIUM AND SILVER IONS IN VARIOUS SAMPLES BY FAAS
title_full USING AN INDOL DERIVATIVE AS COMPLEXING AGENT FOR CLOUD POINT PRECONCENTRATION AND DETERMINATION OF MAGNESIUM AND SILVER IONS IN VARIOUS SAMPLES BY FAAS
title_fullStr USING AN INDOL DERIVATIVE AS COMPLEXING AGENT FOR CLOUD POINT PRECONCENTRATION AND DETERMINATION OF MAGNESIUM AND SILVER IONS IN VARIOUS SAMPLES BY FAAS
title_full_unstemmed USING AN INDOL DERIVATIVE AS COMPLEXING AGENT FOR CLOUD POINT PRECONCENTRATION AND DETERMINATION OF MAGNESIUM AND SILVER IONS IN VARIOUS SAMPLES BY FAAS
title_sort using an indol derivative as complexing agent for cloud point preconcentration and determination of magnesium and silver ions in various samples by faas
publisher Sociedad Chilena de Química
publishDate 2012
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000200017
work_keys_str_mv AT shokrollahiardeshir usinganindolderivativeascomplexingagentforcloudpointpreconcentrationanddeterminationofmagnesiumandsilverionsinvarioussamplesbyfaas
AT tavallalihossein usinganindolderivativeascomplexingagentforcloudpointpreconcentrationanddeterminationofmagnesiumandsilverionsinvarioussamplesbyfaas
AT montaserizohreh usinganindolderivativeascomplexingagentforcloudpointpreconcentrationanddeterminationofmagnesiumandsilverionsinvarioussamplesbyfaas
AT niknamkhodabakhsh usinganindolderivativeascomplexingagentforcloudpointpreconcentrationanddeterminationofmagnesiumandsilverionsinvarioussamplesbyfaas
_version_ 1718445465510346752