ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS
The construction and performance characteristics of simvastatin (SIM) selective electrodes were developed. Three types of electrodes: plastic membrane I, coated wire II, and coated graphite rod III were constructed based on the incorporation of simvastatin with phosphotungstic (PTA) or phosphomolybd...
Guardado en:
Autores principales: | , , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2012
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000200018 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072012000200018 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720120002000182014-03-10ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDSALARFAJ,NAWAL AALY,FATMA AEL-TOHAMY,MAHA Plastic membrane Coated wire electrode Coated graphite rod Ion-selective electrodes Simvastatin Potentiometric determination The construction and performance characteristics of simvastatin (SIM) selective electrodes were developed. Three types of electrodes: plastic membrane I, coated wire II, and coated graphite rod III were constructed based on the incorporation of simvastatin with phosphotungstic (PTA) or phosphomolybdic (PMA) acids and mixed ion pair (PTA/PMA) for the three electrodes, respectively. The influence of membrane composition, kind of plasticizer, type of ion-pair, pH of the test solution, soaking time, and foreign ions on the electrodes was investigated. The electrodes showed a Nernstain response with a mean calibration graph slope of 56.24±0.43, 55.44±0.14 and 58.93±0.34 mV decade-1 at 25°C over simvastatin concentration range from 1.0 x 10-6-5.0 x 10-2, 9.0 x 10-6-5.0 x 10-3 and 9.0 x 10-7-1.0 x 10-2 mol L-1, with detection limit of 5.0 x 10-7, 3.9 x 10-6 and 3.2 x 10-7 mol L-1 for electrode I, II and III, respectively. The pH range for the proposed electrodes was 4-7. The influence of possible interfering species such as common inorganic cations, many sugars, amino acids and a pharmacologically related drug 'ezetimibe' was studied. Statistical student's t-test and F test showed insignificant systematic error between proposed and official methods.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.57 n.2 20122012-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000200018en10.4067/S0717-97072012000200018 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Plastic membrane Coated wire electrode Coated graphite rod Ion-selective electrodes Simvastatin Potentiometric determination |
spellingShingle |
Plastic membrane Coated wire electrode Coated graphite rod Ion-selective electrodes Simvastatin Potentiometric determination ALARFAJ,NAWAL A ALY,FATMA A EL-TOHAMY,MAHA ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS |
description |
The construction and performance characteristics of simvastatin (SIM) selective electrodes were developed. Three types of electrodes: plastic membrane I, coated wire II, and coated graphite rod III were constructed based on the incorporation of simvastatin with phosphotungstic (PTA) or phosphomolybdic (PMA) acids and mixed ion pair (PTA/PMA) for the three electrodes, respectively. The influence of membrane composition, kind of plasticizer, type of ion-pair, pH of the test solution, soaking time, and foreign ions on the electrodes was investigated. The electrodes showed a Nernstain response with a mean calibration graph slope of 56.24±0.43, 55.44±0.14 and 58.93±0.34 mV decade-1 at 25°C over simvastatin concentration range from 1.0 x 10-6-5.0 x 10-2, 9.0 x 10-6-5.0 x 10-3 and 9.0 x 10-7-1.0 x 10-2 mol L-1, with detection limit of 5.0 x 10-7, 3.9 x 10-6 and 3.2 x 10-7 mol L-1 for electrode I, II and III, respectively. The pH range for the proposed electrodes was 4-7. The influence of possible interfering species such as common inorganic cations, many sugars, amino acids and a pharmacologically related drug 'ezetimibe' was studied. Statistical student's t-test and F test showed insignificant systematic error between proposed and official methods. |
author |
ALARFAJ,NAWAL A ALY,FATMA A EL-TOHAMY,MAHA |
author_facet |
ALARFAJ,NAWAL A ALY,FATMA A EL-TOHAMY,MAHA |
author_sort |
ALARFAJ,NAWAL A |
title |
ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS |
title_short |
ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS |
title_full |
ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS |
title_fullStr |
ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS |
title_full_unstemmed |
ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS |
title_sort |
electrochemical sensors for direct determination of simvastatin in pharmaceutical formulations and biological fluids |
publisher |
Sociedad Chilena de Química |
publishDate |
2012 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000200018 |
work_keys_str_mv |
AT alarfajnawala electrochemicalsensorsfordirectdeterminationofsimvastatininpharmaceuticalformulationsandbiologicalfluids AT alyfatmaa electrochemicalsensorsfordirectdeterminationofsimvastatininpharmaceuticalformulationsandbiologicalfluids AT eltohamymaha electrochemicalsensorsfordirectdeterminationofsimvastatininpharmaceuticalformulationsandbiologicalfluids |
_version_ |
1718445465695944704 |