ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS

The construction and performance characteristics of simvastatin (SIM) selective electrodes were developed. Three types of electrodes: plastic membrane I, coated wire II, and coated graphite rod III were constructed based on the incorporation of simvastatin with phosphotungstic (PTA) or phosphomolybd...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: ALARFAJ,NAWAL A, ALY,FATMA A, EL-TOHAMY,MAHA
Lenguaje:English
Publicado: Sociedad Chilena de Química 2012
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000200018
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072012000200018
record_format dspace
spelling oai:scielo:S0717-970720120002000182014-03-10ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDSALARFAJ,NAWAL AALY,FATMA AEL-TOHAMY,MAHA Plastic membrane Coated wire electrode Coated graphite rod Ion-selective electrodes Simvastatin Potentiometric determination The construction and performance characteristics of simvastatin (SIM) selective electrodes were developed. Three types of electrodes: plastic membrane I, coated wire II, and coated graphite rod III were constructed based on the incorporation of simvastatin with phosphotungstic (PTA) or phosphomolybdic (PMA) acids and mixed ion pair (PTA/PMA) for the three electrodes, respectively. The influence of membrane composition, kind of plasticizer, type of ion-pair, pH of the test solution, soaking time, and foreign ions on the electrodes was investigated. The electrodes showed a Nernstain response with a mean calibration graph slope of 56.24±0.43, 55.44±0.14 and 58.93±0.34 mV decade-1 at 25°C over simvastatin concentration range from 1.0 x 10-6-5.0 x 10-2, 9.0 x 10-6-5.0 x 10-3 and 9.0 x 10-7-1.0 x 10-2 mol L-1, with detection limit of 5.0 x 10-7, 3.9 x 10-6 and 3.2 x 10-7 mol L-1 for electrode I, II and III, respectively. The pH range for the proposed electrodes was 4-7. The influence of possible interfering species such as common inorganic cations, many sugars, amino acids and a pharmacologically related drug 'ezetimibe' was studied. Statistical student's t-test and F test showed insignificant systematic error between proposed and official methods.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.57 n.2 20122012-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000200018en10.4067/S0717-97072012000200018
institution Scielo Chile
collection Scielo Chile
language English
topic Plastic membrane
Coated wire electrode
Coated graphite rod
Ion-selective electrodes
Simvastatin
Potentiometric determination
spellingShingle Plastic membrane
Coated wire electrode
Coated graphite rod
Ion-selective electrodes
Simvastatin
Potentiometric determination
ALARFAJ,NAWAL A
ALY,FATMA A
EL-TOHAMY,MAHA
ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS
description The construction and performance characteristics of simvastatin (SIM) selective electrodes were developed. Three types of electrodes: plastic membrane I, coated wire II, and coated graphite rod III were constructed based on the incorporation of simvastatin with phosphotungstic (PTA) or phosphomolybdic (PMA) acids and mixed ion pair (PTA/PMA) for the three electrodes, respectively. The influence of membrane composition, kind of plasticizer, type of ion-pair, pH of the test solution, soaking time, and foreign ions on the electrodes was investigated. The electrodes showed a Nernstain response with a mean calibration graph slope of 56.24±0.43, 55.44±0.14 and 58.93±0.34 mV decade-1 at 25°C over simvastatin concentration range from 1.0 x 10-6-5.0 x 10-2, 9.0 x 10-6-5.0 x 10-3 and 9.0 x 10-7-1.0 x 10-2 mol L-1, with detection limit of 5.0 x 10-7, 3.9 x 10-6 and 3.2 x 10-7 mol L-1 for electrode I, II and III, respectively. The pH range for the proposed electrodes was 4-7. The influence of possible interfering species such as common inorganic cations, many sugars, amino acids and a pharmacologically related drug 'ezetimibe' was studied. Statistical student's t-test and F test showed insignificant systematic error between proposed and official methods.
author ALARFAJ,NAWAL A
ALY,FATMA A
EL-TOHAMY,MAHA
author_facet ALARFAJ,NAWAL A
ALY,FATMA A
EL-TOHAMY,MAHA
author_sort ALARFAJ,NAWAL A
title ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS
title_short ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS
title_full ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS
title_fullStr ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS
title_full_unstemmed ELECTROCHEMICAL SENSORS FOR DIRECT DETERMINATION OF SIMVASTATIN IN PHARMACEUTICAL FORMULATIONS AND BIOLOGICAL FLUIDS
title_sort electrochemical sensors for direct determination of simvastatin in pharmaceutical formulations and biological fluids
publisher Sociedad Chilena de Química
publishDate 2012
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000200018
work_keys_str_mv AT alarfajnawala electrochemicalsensorsfordirectdeterminationofsimvastatininpharmaceuticalformulationsandbiologicalfluids
AT alyfatmaa electrochemicalsensorsfordirectdeterminationofsimvastatininpharmaceuticalformulationsandbiologicalfluids
AT eltohamymaha electrochemicalsensorsfordirectdeterminationofsimvastatininpharmaceuticalformulationsandbiologicalfluids
_version_ 1718445465695944704