RAPID ANALYSIS OF FINASTERIDE IN BULK AND FORMULATIONS BY RP-HPLC-PDA METHOD
A simple, precise, rapid and accurate LC-MS compatible RP-HPLC-PDA method has been developed and validated for the estimation of Finasteride (FIN) in bulk and tablet formulations. The chromatographic separation was achieved on Phenomenex C18 column (150 mm x 4.6 mm, 5.0 µ particle size) using the mo...
Guardado en:
Autores principales: | , , , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2012
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000400027 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072012000400027 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720120004000272013-04-04RAPID ANALYSIS OF FINASTERIDE IN BULK AND FORMULATIONS BY RP-HPLC-PDA METHODMANNE,SINDHURAKAKARLA,RAGHAVIIRAAVI,PRASHANTHNALLURI,BUCHI N Rapid Finasteride HPLC validation LC-MS compatible Phenomenex C18 column 220nm A simple, precise, rapid and accurate LC-MS compatible RP-HPLC-PDA method has been developed and validated for the estimation of Finasteride (FIN) in bulk and tablet formulations. The chromatographic separation was achieved on Phenomenex C18 column (150 mm x 4.6 mm, 5.0 µ particle size) using the mobile phase comprising 0.02% formic acid (in water): methanol in the ratio of 20:80 (v/v) at a flow rate of 1mL/min and FIN was eluted at 3.4 min. Quantification and linearity were achieved at 220 nm over the concentration range of 5-50 µg/mL and the percentage mean of assay was found to be 100.29. The method was validated for specificity, linearity, accuracy, precision, LOD, LOQ, stability and robustness as per the ICH guidelines and is suitable to be employed in Quality Control.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.57 n.4 20122012-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000400027en10.4067/S0717-97072012000400027 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Rapid Finasteride HPLC validation LC-MS compatible Phenomenex C18 column 220nm |
spellingShingle |
Rapid Finasteride HPLC validation LC-MS compatible Phenomenex C18 column 220nm MANNE,SINDHURA KAKARLA,RAGHAVI IRAAVI,PRASHANTH NALLURI,BUCHI N RAPID ANALYSIS OF FINASTERIDE IN BULK AND FORMULATIONS BY RP-HPLC-PDA METHOD |
description |
A simple, precise, rapid and accurate LC-MS compatible RP-HPLC-PDA method has been developed and validated for the estimation of Finasteride (FIN) in bulk and tablet formulations. The chromatographic separation was achieved on Phenomenex C18 column (150 mm x 4.6 mm, 5.0 µ particle size) using the mobile phase comprising 0.02% formic acid (in water): methanol in the ratio of 20:80 (v/v) at a flow rate of 1mL/min and FIN was eluted at 3.4 min. Quantification and linearity were achieved at 220 nm over the concentration range of 5-50 µg/mL and the percentage mean of assay was found to be 100.29. The method was validated for specificity, linearity, accuracy, precision, LOD, LOQ, stability and robustness as per the ICH guidelines and is suitable to be employed in Quality Control. |
author |
MANNE,SINDHURA KAKARLA,RAGHAVI IRAAVI,PRASHANTH NALLURI,BUCHI N |
author_facet |
MANNE,SINDHURA KAKARLA,RAGHAVI IRAAVI,PRASHANTH NALLURI,BUCHI N |
author_sort |
MANNE,SINDHURA |
title |
RAPID ANALYSIS OF FINASTERIDE IN BULK AND FORMULATIONS BY RP-HPLC-PDA METHOD |
title_short |
RAPID ANALYSIS OF FINASTERIDE IN BULK AND FORMULATIONS BY RP-HPLC-PDA METHOD |
title_full |
RAPID ANALYSIS OF FINASTERIDE IN BULK AND FORMULATIONS BY RP-HPLC-PDA METHOD |
title_fullStr |
RAPID ANALYSIS OF FINASTERIDE IN BULK AND FORMULATIONS BY RP-HPLC-PDA METHOD |
title_full_unstemmed |
RAPID ANALYSIS OF FINASTERIDE IN BULK AND FORMULATIONS BY RP-HPLC-PDA METHOD |
title_sort |
rapid analysis of finasteride in bulk and formulations by rp-hplc-pda method |
publisher |
Sociedad Chilena de Química |
publishDate |
2012 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072012000400027 |
work_keys_str_mv |
AT mannesindhura rapidanalysisoffinasterideinbulkandformulationsbyrphplcpdamethod AT kakarlaraghavi rapidanalysisoffinasterideinbulkandformulationsbyrphplcpdamethod AT iraaviprashanth rapidanalysisoffinasterideinbulkandformulationsbyrphplcpdamethod AT nalluribuchin rapidanalysisoffinasterideinbulkandformulationsbyrphplcpdamethod |
_version_ |
1718445477697945600 |