BEHAVIOR OF A POLYMERIC LIQUID MEMBRANE ION- SELECTIVE ELECTRODE FOR CHLORIDE ION
Chloride selective polymeric liquid membrane electrode has been developed by using Bis-(2-ethylhexyl) Sebacate (DOS) as plasticizer and 2-[5-(4-nitrophenyl) furyl]-4,5-diphenyl imidazole (FFDFIN) as ionophore. Some parameters of evaluation of the electrode are presented in this work. The constructed...
Guardado en:
Autores principales: | , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2013
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072013000400009 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072013000400009 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720130004000092014-09-02BEHAVIOR OF A POLYMERIC LIQUID MEMBRANE ION- SELECTIVE ELECTRODE FOR CHLORIDE IONARADA PÉREZ,M. DE LOS AYAZDANI-PEDRAM,M Chloride ion selective PVC membrane Ion-selective electrode (ISE) 2-[5-(4-nitrophenyl)furyl] -4,5-diphenyl imidazole Chloride selective polymeric liquid membrane electrode has been developed by using Bis-(2-ethylhexyl) Sebacate (DOS) as plasticizer and 2-[5-(4-nitrophenyl) furyl]-4,5-diphenyl imidazole (FFDFIN) as ionophore. Some parameters of evaluation of the electrode are presented in this work. The constructed electrode showed fast potentiometric response to chloride ion in the concentration range from 10-6 to 10-2 mol.dm-3 with Nernstian slope of -63.43 ± 0.85 mV/decade, response time of 25 seconds and life time of 15 days.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.58 n.4 20132013-12-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072013000400009en10.4067/S0717-97072013000400009 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Chloride ion selective PVC membrane Ion-selective electrode (ISE) 2-[5-(4-nitrophenyl)furyl] -4,5-diphenyl imidazole |
spellingShingle |
Chloride ion selective PVC membrane Ion-selective electrode (ISE) 2-[5-(4-nitrophenyl)furyl] -4,5-diphenyl imidazole ARADA PÉREZ,M. DE LOS A YAZDANI-PEDRAM,M BEHAVIOR OF A POLYMERIC LIQUID MEMBRANE ION- SELECTIVE ELECTRODE FOR CHLORIDE ION |
description |
Chloride selective polymeric liquid membrane electrode has been developed by using Bis-(2-ethylhexyl) Sebacate (DOS) as plasticizer and 2-[5-(4-nitrophenyl) furyl]-4,5-diphenyl imidazole (FFDFIN) as ionophore. Some parameters of evaluation of the electrode are presented in this work. The constructed electrode showed fast potentiometric response to chloride ion in the concentration range from 10-6 to 10-2 mol.dm-3 with Nernstian slope of -63.43 ± 0.85 mV/decade, response time of 25 seconds and life time of 15 days. |
author |
ARADA PÉREZ,M. DE LOS A YAZDANI-PEDRAM,M |
author_facet |
ARADA PÉREZ,M. DE LOS A YAZDANI-PEDRAM,M |
author_sort |
ARADA PÉREZ,M. DE LOS A |
title |
BEHAVIOR OF A POLYMERIC LIQUID MEMBRANE ION- SELECTIVE ELECTRODE FOR CHLORIDE ION |
title_short |
BEHAVIOR OF A POLYMERIC LIQUID MEMBRANE ION- SELECTIVE ELECTRODE FOR CHLORIDE ION |
title_full |
BEHAVIOR OF A POLYMERIC LIQUID MEMBRANE ION- SELECTIVE ELECTRODE FOR CHLORIDE ION |
title_fullStr |
BEHAVIOR OF A POLYMERIC LIQUID MEMBRANE ION- SELECTIVE ELECTRODE FOR CHLORIDE ION |
title_full_unstemmed |
BEHAVIOR OF A POLYMERIC LIQUID MEMBRANE ION- SELECTIVE ELECTRODE FOR CHLORIDE ION |
title_sort |
behavior of a polymeric liquid membrane ion- selective electrode for chloride ion |
publisher |
Sociedad Chilena de Química |
publishDate |
2013 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072013000400009 |
work_keys_str_mv |
AT aradaperezmdelosa behaviorofapolymericliquidmembraneionselectiveelectrodeforchlorideion AT yazdanipedramm behaviorofapolymericliquidmembraneionselectiveelectrodeforchlorideion |
_version_ |
1718445497865207808 |