METHODOLOGICAL VALIDATION FOR THE DETERMINATION OF TOXIC ARSENIC SPECIES IN HUMAN URINE USING HPLC WITH ICP-MS

There is a significant amount of arsenic species in the environment and in biological systems; however, the toxicity and possibly the carcinogenicity of ingested arsenic depend on the species and the oxidation state. Therefore, analytical methodologies and techniques that are fast and robust, that i...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: MUÑOZ,LUIS, MENESES,MACARENA, PISMANTE,PAOLA, ANDONIE,OSCAR, QUEIROLO,FABRIZIO, STEGEN,SUSANA
Lenguaje:English
Publicado: Sociedad Chilena de Química 2014
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072014000200007
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072014000200007
record_format dspace
spelling oai:scielo:S0717-970720140002000072014-11-05METHODOLOGICAL VALIDATION FOR THE DETERMINATION OF TOXIC ARSENIC SPECIES IN HUMAN URINE USING HPLC WITH ICP-MSMUÑOZ,LUISMENESES,MACARENAPISMANTE,PAOLAANDONIE,OSCARQUEIROLO,FABRIZIOSTEGEN,SUSANA methodological validation arsenic species human urine HPLC ICP-MS There is a significant amount of arsenic species in the environment and in biological systems; however, the toxicity and possibly the carcinogenicity of ingested arsenic depend on the species and the oxidation state. Therefore, analytical methodologies and techniques that are fast and robust, that involve highly efficient separation and are powerful tools of detection are necessary for the correct quantification of individual arsenic species. The field of speciation analysis of arsenic in this area has grown rapidly in recent years, especially with the application of liquid chromatography and mass spectrometry with inductively coupled plasma. This study aimed to develop and apply this technique to human urine samples in order to reduce the treatment needed for speciation, maintain maximum recovery and avoid interconversion and / or degradation between species. In order to optimize the separation of species, several experiments were performed by preparing the mobile phase at different pH values. The optimal pH value and the linearity of the method were determined and the methodology was validated using a Certified Reference Material. Student's t-test and Fisher F-test for determination of accuracy and precision were applied. A simple, rapid and reliable method for the separation and quantification of several species of arsenic, As III (Arsenite), As V (Arsenate), MMA (Monomethyl Arsonic Acid), DMA (Dimethyl Arsinic Acid), AB (Arsenobetaine) was developed in human urine samples with minimal prior sample preparation. The time required for sample processing and isocratic chromatographic analysis is about 15 minutes. Detection limits of 0.020 μgL-1 of AsB, 0.020 μgL-1 of As III, 0.040 μgL-1 of DMA, 0.060 μgL-1 of MMA and 0.060 μgL-1 of As V were achieved under the analytical conditions mentioned above.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.59 n.2 20142014-07-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072014000200007en10.4067/S0717-97072014000200007
institution Scielo Chile
collection Scielo Chile
language English
topic methodological validation
arsenic species
human urine
HPLC
ICP-MS
spellingShingle methodological validation
arsenic species
human urine
HPLC
ICP-MS
MUÑOZ,LUIS
MENESES,MACARENA
PISMANTE,PAOLA
ANDONIE,OSCAR
QUEIROLO,FABRIZIO
STEGEN,SUSANA
METHODOLOGICAL VALIDATION FOR THE DETERMINATION OF TOXIC ARSENIC SPECIES IN HUMAN URINE USING HPLC WITH ICP-MS
description There is a significant amount of arsenic species in the environment and in biological systems; however, the toxicity and possibly the carcinogenicity of ingested arsenic depend on the species and the oxidation state. Therefore, analytical methodologies and techniques that are fast and robust, that involve highly efficient separation and are powerful tools of detection are necessary for the correct quantification of individual arsenic species. The field of speciation analysis of arsenic in this area has grown rapidly in recent years, especially with the application of liquid chromatography and mass spectrometry with inductively coupled plasma. This study aimed to develop and apply this technique to human urine samples in order to reduce the treatment needed for speciation, maintain maximum recovery and avoid interconversion and / or degradation between species. In order to optimize the separation of species, several experiments were performed by preparing the mobile phase at different pH values. The optimal pH value and the linearity of the method were determined and the methodology was validated using a Certified Reference Material. Student's t-test and Fisher F-test for determination of accuracy and precision were applied. A simple, rapid and reliable method for the separation and quantification of several species of arsenic, As III (Arsenite), As V (Arsenate), MMA (Monomethyl Arsonic Acid), DMA (Dimethyl Arsinic Acid), AB (Arsenobetaine) was developed in human urine samples with minimal prior sample preparation. The time required for sample processing and isocratic chromatographic analysis is about 15 minutes. Detection limits of 0.020 μgL-1 of AsB, 0.020 μgL-1 of As III, 0.040 μgL-1 of DMA, 0.060 μgL-1 of MMA and 0.060 μgL-1 of As V were achieved under the analytical conditions mentioned above.
author MUÑOZ,LUIS
MENESES,MACARENA
PISMANTE,PAOLA
ANDONIE,OSCAR
QUEIROLO,FABRIZIO
STEGEN,SUSANA
author_facet MUÑOZ,LUIS
MENESES,MACARENA
PISMANTE,PAOLA
ANDONIE,OSCAR
QUEIROLO,FABRIZIO
STEGEN,SUSANA
author_sort MUÑOZ,LUIS
title METHODOLOGICAL VALIDATION FOR THE DETERMINATION OF TOXIC ARSENIC SPECIES IN HUMAN URINE USING HPLC WITH ICP-MS
title_short METHODOLOGICAL VALIDATION FOR THE DETERMINATION OF TOXIC ARSENIC SPECIES IN HUMAN URINE USING HPLC WITH ICP-MS
title_full METHODOLOGICAL VALIDATION FOR THE DETERMINATION OF TOXIC ARSENIC SPECIES IN HUMAN URINE USING HPLC WITH ICP-MS
title_fullStr METHODOLOGICAL VALIDATION FOR THE DETERMINATION OF TOXIC ARSENIC SPECIES IN HUMAN URINE USING HPLC WITH ICP-MS
title_full_unstemmed METHODOLOGICAL VALIDATION FOR THE DETERMINATION OF TOXIC ARSENIC SPECIES IN HUMAN URINE USING HPLC WITH ICP-MS
title_sort methodological validation for the determination of toxic arsenic species in human urine using hplc with icp-ms
publisher Sociedad Chilena de Química
publishDate 2014
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072014000200007
work_keys_str_mv AT munozluis methodologicalvalidationforthedeterminationoftoxicarsenicspeciesinhumanurineusinghplcwithicpms
AT menesesmacarena methodologicalvalidationforthedeterminationoftoxicarsenicspeciesinhumanurineusinghplcwithicpms
AT pismantepaola methodologicalvalidationforthedeterminationoftoxicarsenicspeciesinhumanurineusinghplcwithicpms
AT andonieoscar methodologicalvalidationforthedeterminationoftoxicarsenicspeciesinhumanurineusinghplcwithicpms
AT queirolofabrizio methodologicalvalidationforthedeterminationoftoxicarsenicspeciesinhumanurineusinghplcwithicpms
AT stegensusana methodologicalvalidationforthedeterminationoftoxicarsenicspeciesinhumanurineusinghplcwithicpms
_version_ 1718445516351602688