A SENSITIVE SEQUENTIAL INJECTION ANALYSIS (SIA) DETERMINATION OF MEMANTINE HYDROCHLORIDE USING LUMINOL-HYDROGEN PEROXIDE INDUCED CHEMILUMINESCENCE DETECTION

A fully automated sequential injection analysis (SIA) method for chemiluminescence (CL) determination of Al-zheimer's drug memantine hydrochloride was developed and presented. The employing of SIA injection analysis facilitates fluidic handling and lowering the consumption of sample and reagent...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: ALARFAJ,NAWAL A, EL-TOHAMY,MAHA F
Lenguaje:English
Publicado: Sociedad Chilena de Química 2014
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072014000400006
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072014000400006
record_format dspace
spelling oai:scielo:S0717-970720140004000062015-01-09A SENSITIVE SEQUENTIAL INJECTION ANALYSIS (SIA) DETERMINATION OF MEMANTINE HYDROCHLORIDE USING LUMINOL-HYDROGEN PEROXIDE INDUCED CHEMILUMINESCENCE DETECTIONALARFAJ,NAWAL AEL-TOHAMY,MAHA F Sequential injection analysis Chemiluminescence determination Memantine hydrochloride Pharmaceutical formulations A fully automated sequential injection analysis (SIA) method for chemiluminescence (CL) determination of Al-zheimer's drug memantine hydrochloride was developed and presented. The employing of SIA injection analysis facilitates fluidic handling and lowering the consumption of sample and reagents. The basic CL reaction was based on the emission of CL radiation due to the reaction of luminol with hydrogen peroxide in basic medium. The CL emission has been monitored using FIAlab system. The optimum conditions and characterizations were optimized using a computer-aided simplex method. Under the optimal conditions the linear calibration graph was obtained within the range of 0.0001-1.0 μg mL-1, (r=0.9996) with detection limit of 3.3x10-5 μg mL-1 along with relative standard deviation 1.8 % (n). The flow rates were 120 μL s-1, for the aspiration into the holding coil and 80 μL s-1 for detection. The sample frequency throughput was 103 h-1. The proposed CL method was successfully applied for determination of the tested drug in pure form and its pharmaceutical formulations. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated. No interference was recorded. The obtained SIA results were statistically compared with those obtained from a reported method and did not show any significant difference.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.59 n.4 20142014-12-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072014000400006en10.4067/S0717-97072014000400006
institution Scielo Chile
collection Scielo Chile
language English
topic Sequential injection analysis
Chemiluminescence determination
Memantine hydrochloride
Pharmaceutical formulations
spellingShingle Sequential injection analysis
Chemiluminescence determination
Memantine hydrochloride
Pharmaceutical formulations
ALARFAJ,NAWAL A
EL-TOHAMY,MAHA F
A SENSITIVE SEQUENTIAL INJECTION ANALYSIS (SIA) DETERMINATION OF MEMANTINE HYDROCHLORIDE USING LUMINOL-HYDROGEN PEROXIDE INDUCED CHEMILUMINESCENCE DETECTION
description A fully automated sequential injection analysis (SIA) method for chemiluminescence (CL) determination of Al-zheimer's drug memantine hydrochloride was developed and presented. The employing of SIA injection analysis facilitates fluidic handling and lowering the consumption of sample and reagents. The basic CL reaction was based on the emission of CL radiation due to the reaction of luminol with hydrogen peroxide in basic medium. The CL emission has been monitored using FIAlab system. The optimum conditions and characterizations were optimized using a computer-aided simplex method. Under the optimal conditions the linear calibration graph was obtained within the range of 0.0001-1.0 μg mL-1, (r=0.9996) with detection limit of 3.3x10-5 μg mL-1 along with relative standard deviation 1.8 % (n). The flow rates were 120 μL s-1, for the aspiration into the holding coil and 80 μL s-1 for detection. The sample frequency throughput was 103 h-1. The proposed CL method was successfully applied for determination of the tested drug in pure form and its pharmaceutical formulations. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated. No interference was recorded. The obtained SIA results were statistically compared with those obtained from a reported method and did not show any significant difference.
author ALARFAJ,NAWAL A
EL-TOHAMY,MAHA F
author_facet ALARFAJ,NAWAL A
EL-TOHAMY,MAHA F
author_sort ALARFAJ,NAWAL A
title A SENSITIVE SEQUENTIAL INJECTION ANALYSIS (SIA) DETERMINATION OF MEMANTINE HYDROCHLORIDE USING LUMINOL-HYDROGEN PEROXIDE INDUCED CHEMILUMINESCENCE DETECTION
title_short A SENSITIVE SEQUENTIAL INJECTION ANALYSIS (SIA) DETERMINATION OF MEMANTINE HYDROCHLORIDE USING LUMINOL-HYDROGEN PEROXIDE INDUCED CHEMILUMINESCENCE DETECTION
title_full A SENSITIVE SEQUENTIAL INJECTION ANALYSIS (SIA) DETERMINATION OF MEMANTINE HYDROCHLORIDE USING LUMINOL-HYDROGEN PEROXIDE INDUCED CHEMILUMINESCENCE DETECTION
title_fullStr A SENSITIVE SEQUENTIAL INJECTION ANALYSIS (SIA) DETERMINATION OF MEMANTINE HYDROCHLORIDE USING LUMINOL-HYDROGEN PEROXIDE INDUCED CHEMILUMINESCENCE DETECTION
title_full_unstemmed A SENSITIVE SEQUENTIAL INJECTION ANALYSIS (SIA) DETERMINATION OF MEMANTINE HYDROCHLORIDE USING LUMINOL-HYDROGEN PEROXIDE INDUCED CHEMILUMINESCENCE DETECTION
title_sort sensitive sequential injection analysis (sia) determination of memantine hydrochloride using luminol-hydrogen peroxide induced chemiluminescence detection
publisher Sociedad Chilena de Química
publishDate 2014
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072014000400006
work_keys_str_mv AT alarfajnawala asensitivesequentialinjectionanalysissiadeterminationofmemantinehydrochlorideusingluminolhydrogenperoxideinducedchemiluminescencedetection
AT eltohamymahaf asensitivesequentialinjectionanalysissiadeterminationofmemantinehydrochlorideusingluminolhydrogenperoxideinducedchemiluminescencedetection
AT alarfajnawala sensitivesequentialinjectionanalysissiadeterminationofmemantinehydrochlorideusingluminolhydrogenperoxideinducedchemiluminescencedetection
AT eltohamymahaf sensitivesequentialinjectionanalysissiadeterminationofmemantinehydrochlorideusingluminolhydrogenperoxideinducedchemiluminescencedetection
_version_ 1718445525832826880