FLOW-INJECTION SPECTROMETRIC DETERMINATION OF SODIUM DICLOFENAC IN PHARMACEUTICAL FORMULATIONS

ABSTRACT A flow-injection spectrometric method for determination of sodium diclofenac in pharmaceutical formulations was developed on this work. Sodium diclofenac solutions were injected into a stream of deionized water that reacted with potassium permanganate on acid medium producing Mn2+ ions whos...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Silva,E. F., Gomes,P. R. B., Fernandes,R. N., Lyra,W. S.
Lenguaje:English
Publicado: Sociedad Chilena de Química 2018
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072018000203941
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072018000203941
record_format dspace
spelling oai:scielo:S0717-970720180002039412018-07-19FLOW-INJECTION SPECTROMETRIC DETERMINATION OF SODIUM DICLOFENAC IN PHARMACEUTICAL FORMULATIONSSilva,E. F.Gomes,P. R. B.Fernandes,R. N.Lyra,W. S. Sodium diclofenac flow-injection analysis injectable solutions tablets ABSTRACT A flow-injection spectrometric method for determination of sodium diclofenac in pharmaceutical formulations was developed on this work. Sodium diclofenac solutions were injected into a stream of deionized water that reacted with potassium permanganate on acid medium producing Mn2+ ions whose exhibit maximum absorbance at 450 nm. The methodology used optimize experimental parameters was 33 factorial design and response surface. The proposed method obeyed the Beer's Law over the range 25-160 mg L–1, applied in tablets and ampoules samples. Results were compare with the reference method. It was verified at the 95% confidence level, through paired t-test application - there is no statistic difference between them. The detection limit was valued in 2.6 mg L–1, relative standard deviation for 10 consecutive injections was 1.5% (100.0 mg L–1 sodium diclofenac solution) and the sample throughput was 80 samples h–1. Regarding optimization of operational conditions, the FIA spectrometric method presented analytical performance as good as other elaborated flow analyzers. Offers a simple and inexpensive way to this drug indirect determination aiming quality control on pharmaceutical industry's assembly line. However, it can not be used for adulteration screening analysis due to non-selectivity and non-specificity of redox reactions.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.63 n.2 20182018-06-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072018000203941en10.4067/s0717-97072018000203941
institution Scielo Chile
collection Scielo Chile
language English
topic Sodium diclofenac
flow-injection analysis
injectable solutions
tablets
spellingShingle Sodium diclofenac
flow-injection analysis
injectable solutions
tablets
Silva,E. F.
Gomes,P. R. B.
Fernandes,R. N.
Lyra,W. S.
FLOW-INJECTION SPECTROMETRIC DETERMINATION OF SODIUM DICLOFENAC IN PHARMACEUTICAL FORMULATIONS
description ABSTRACT A flow-injection spectrometric method for determination of sodium diclofenac in pharmaceutical formulations was developed on this work. Sodium diclofenac solutions were injected into a stream of deionized water that reacted with potassium permanganate on acid medium producing Mn2+ ions whose exhibit maximum absorbance at 450 nm. The methodology used optimize experimental parameters was 33 factorial design and response surface. The proposed method obeyed the Beer's Law over the range 25-160 mg L–1, applied in tablets and ampoules samples. Results were compare with the reference method. It was verified at the 95% confidence level, through paired t-test application - there is no statistic difference between them. The detection limit was valued in 2.6 mg L–1, relative standard deviation for 10 consecutive injections was 1.5% (100.0 mg L–1 sodium diclofenac solution) and the sample throughput was 80 samples h–1. Regarding optimization of operational conditions, the FIA spectrometric method presented analytical performance as good as other elaborated flow analyzers. Offers a simple and inexpensive way to this drug indirect determination aiming quality control on pharmaceutical industry's assembly line. However, it can not be used for adulteration screening analysis due to non-selectivity and non-specificity of redox reactions.
author Silva,E. F.
Gomes,P. R. B.
Fernandes,R. N.
Lyra,W. S.
author_facet Silva,E. F.
Gomes,P. R. B.
Fernandes,R. N.
Lyra,W. S.
author_sort Silva,E. F.
title FLOW-INJECTION SPECTROMETRIC DETERMINATION OF SODIUM DICLOFENAC IN PHARMACEUTICAL FORMULATIONS
title_short FLOW-INJECTION SPECTROMETRIC DETERMINATION OF SODIUM DICLOFENAC IN PHARMACEUTICAL FORMULATIONS
title_full FLOW-INJECTION SPECTROMETRIC DETERMINATION OF SODIUM DICLOFENAC IN PHARMACEUTICAL FORMULATIONS
title_fullStr FLOW-INJECTION SPECTROMETRIC DETERMINATION OF SODIUM DICLOFENAC IN PHARMACEUTICAL FORMULATIONS
title_full_unstemmed FLOW-INJECTION SPECTROMETRIC DETERMINATION OF SODIUM DICLOFENAC IN PHARMACEUTICAL FORMULATIONS
title_sort flow-injection spectrometric determination of sodium diclofenac in pharmaceutical formulations
publisher Sociedad Chilena de Química
publishDate 2018
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072018000203941
work_keys_str_mv AT silvaef flowinjectionspectrometricdeterminationofsodiumdiclofenacinpharmaceuticalformulations
AT gomesprb flowinjectionspectrometricdeterminationofsodiumdiclofenacinpharmaceuticalformulations
AT fernandesrn flowinjectionspectrometricdeterminationofsodiumdiclofenacinpharmaceuticalformulations
AT lyraws flowinjectionspectrometricdeterminationofsodiumdiclofenacinpharmaceuticalformulations
_version_ 1714200924562391040