DETERMINATION OF HYDROXYZINE BY DIFFERENTIAL PULSE ANODIC VOLTAMMETRY USING CARBON PASTE ELECTRODE
ABSTRACT The electrochemical oxidation of hydroxyzine dihydrochloride at carbon paste electrode has been studied in 0.04 M Britton-Robinson buffer pH 6.2 using cyclic and differential pulse voltammetry. The oxidation process has been shown to irreversible and diffusion controlled with adsorption cha...
Guardado en:
Autores principales: | , , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2018
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072018000304064 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072018000304064 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720180003040642018-10-03DETERMINATION OF HYDROXYZINE BY DIFFERENTIAL PULSE ANODIC VOLTAMMETRY USING CARBON PASTE ELECTRODEZayed,Sayed I. M.Al-Talhi,Amal A. H.Thagafi,Asmaa E. Al Hydroxyzine dihydrochloride differential pulse anoding voltammetry carbon paste electrodes pharmaceutical dosage form human urine ABSTRACT The electrochemical oxidation of hydroxyzine dihydrochloride at carbon paste electrode has been studied in 0.04 M Britton-Robinson buffer pH 6.2 using cyclic and differential pulse voltammetry. The oxidation process has been shown to irreversible and diffusion controlled with adsorption characterstics. Based on these studies, simple, rapid, and sensitive differential pulse anodic voltammetric method has been developed for the determination of the drug over the concentration range 0.45-5.36 μg/ml, with detection and quantification limits of 0.27 and 0.90 μg/ml hydroxyzine dihydrochloride, respectively. The proposed method was successfully used for quantification of hydroxyzine dihydrochloride in Atarax tablets and spiked human urine.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.63 n.3 20182018-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072018000304064en10.4067/s0717-97072018000304064 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Hydroxyzine dihydrochloride differential pulse anoding voltammetry carbon paste electrodes pharmaceutical dosage form human urine |
spellingShingle |
Hydroxyzine dihydrochloride differential pulse anoding voltammetry carbon paste electrodes pharmaceutical dosage form human urine Zayed,Sayed I. M. Al-Talhi,Amal A. H. Thagafi,Asmaa E. Al DETERMINATION OF HYDROXYZINE BY DIFFERENTIAL PULSE ANODIC VOLTAMMETRY USING CARBON PASTE ELECTRODE |
description |
ABSTRACT The electrochemical oxidation of hydroxyzine dihydrochloride at carbon paste electrode has been studied in 0.04 M Britton-Robinson buffer pH 6.2 using cyclic and differential pulse voltammetry. The oxidation process has been shown to irreversible and diffusion controlled with adsorption characterstics. Based on these studies, simple, rapid, and sensitive differential pulse anodic voltammetric method has been developed for the determination of the drug over the concentration range 0.45-5.36 μg/ml, with detection and quantification limits of 0.27 and 0.90 μg/ml hydroxyzine dihydrochloride, respectively. The proposed method was successfully used for quantification of hydroxyzine dihydrochloride in Atarax tablets and spiked human urine. |
author |
Zayed,Sayed I. M. Al-Talhi,Amal A. H. Thagafi,Asmaa E. Al |
author_facet |
Zayed,Sayed I. M. Al-Talhi,Amal A. H. Thagafi,Asmaa E. Al |
author_sort |
Zayed,Sayed I. M. |
title |
DETERMINATION OF HYDROXYZINE BY DIFFERENTIAL PULSE ANODIC VOLTAMMETRY USING CARBON PASTE ELECTRODE |
title_short |
DETERMINATION OF HYDROXYZINE BY DIFFERENTIAL PULSE ANODIC VOLTAMMETRY USING CARBON PASTE ELECTRODE |
title_full |
DETERMINATION OF HYDROXYZINE BY DIFFERENTIAL PULSE ANODIC VOLTAMMETRY USING CARBON PASTE ELECTRODE |
title_fullStr |
DETERMINATION OF HYDROXYZINE BY DIFFERENTIAL PULSE ANODIC VOLTAMMETRY USING CARBON PASTE ELECTRODE |
title_full_unstemmed |
DETERMINATION OF HYDROXYZINE BY DIFFERENTIAL PULSE ANODIC VOLTAMMETRY USING CARBON PASTE ELECTRODE |
title_sort |
determination of hydroxyzine by differential pulse anodic voltammetry using carbon paste electrode |
publisher |
Sociedad Chilena de Química |
publishDate |
2018 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072018000304064 |
work_keys_str_mv |
AT zayedsayedim determinationofhydroxyzinebydifferentialpulseanodicvoltammetryusingcarbonpasteelectrode AT altalhiamalah determinationofhydroxyzinebydifferentialpulseanodicvoltammetryusingcarbonpasteelectrode AT thagafiasmaaeal determinationofhydroxyzinebydifferentialpulseanodicvoltammetryusingcarbonpasteelectrode |
_version_ |
1714200928068829184 |