SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM
ABSTRACT Risperidone, an antipsychotic drug, was determined in human serum, using an optimized liquid-liquid extraction for isolation from biological fluid, with ethyl acetate as extraction solvent. This sample extraction method was chosen to increase extraction efficiency and reduce matrix interfer...
Guardado en:
Autores principales: | , , , |
---|---|
Lenguaje: | English |
Publicado: |
Sociedad Chilena de Química
2019
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072019000104265 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0717-97072019000104265 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0717-970720190001042652019-04-11SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUMMennickent,SigridDiego,Marta DeLiser,BerndTrujillo,Lina Risperidone human serum liquid chromatography quantitative determination ABSTRACT Risperidone, an antipsychotic drug, was determined in human serum, using an optimized liquid-liquid extraction for isolation from biological fluid, with ethyl acetate as extraction solvent. This sample extraction method was chosen to increase extraction efficiency and reduce matrix interferences. Quantitation was achieved by LC/DAD at 294 nm over the concentration range of 1 ng/mL to 60 ng/mL (r=0.999). Desipramine was used as internal standard (tR for Risperidone: 4.23; tR Desipramine: 7.31). Mobile phase was water: acetonitrile: triethilamine: glacial acetic acid (70:29.16:0.52: 0.33 v/v), using a Purosphere STAR RP-18e 250 × 4.5 mm (5µ) column. RSD, for the intra-assay study, was between 0.52 % – 2.09 % (n=3), and between 0.79 % −3.25 % (n=9) for the inter-assay. LOD was 0.40 ng/mL and LOQ was 0.87 ng/mL. Recovery percentage for the accuracy study was between 90.82% and 98.56% ((RSD ≤ 3.93). The method is simple, fast, precise, accurate, sensible and selective. This method was successfully applied to quantify risperidone in patient serum samples. In conclusion, the method is useful for quantitative determination of risperidone in human serum.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.64 n.1 20192019-03-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072019000104265en10.4067/s0717-97072019000104265 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Risperidone human serum liquid chromatography quantitative determination |
spellingShingle |
Risperidone human serum liquid chromatography quantitative determination Mennickent,Sigrid Diego,Marta De Liser,Bernd Trujillo,Lina SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM |
description |
ABSTRACT Risperidone, an antipsychotic drug, was determined in human serum, using an optimized liquid-liquid extraction for isolation from biological fluid, with ethyl acetate as extraction solvent. This sample extraction method was chosen to increase extraction efficiency and reduce matrix interferences. Quantitation was achieved by LC/DAD at 294 nm over the concentration range of 1 ng/mL to 60 ng/mL (r=0.999). Desipramine was used as internal standard (tR for Risperidone: 4.23; tR Desipramine: 7.31). Mobile phase was water: acetonitrile: triethilamine: glacial acetic acid (70:29.16:0.52: 0.33 v/v), using a Purosphere STAR RP-18e 250 × 4.5 mm (5µ) column. RSD, for the intra-assay study, was between 0.52 % – 2.09 % (n=3), and between 0.79 % −3.25 % (n=9) for the inter-assay. LOD was 0.40 ng/mL and LOQ was 0.87 ng/mL. Recovery percentage for the accuracy study was between 90.82% and 98.56% ((RSD ≤ 3.93). The method is simple, fast, precise, accurate, sensible and selective. This method was successfully applied to quantify risperidone in patient serum samples. In conclusion, the method is useful for quantitative determination of risperidone in human serum. |
author |
Mennickent,Sigrid Diego,Marta De Liser,Bernd Trujillo,Lina |
author_facet |
Mennickent,Sigrid Diego,Marta De Liser,Bernd Trujillo,Lina |
author_sort |
Mennickent,Sigrid |
title |
SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM |
title_short |
SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM |
title_full |
SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM |
title_fullStr |
SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM |
title_full_unstemmed |
SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM |
title_sort |
simplified liquid-liquid extraction method coupled with lc/dad by quantitative determination of risperidone in human serum |
publisher |
Sociedad Chilena de Química |
publishDate |
2019 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072019000104265 |
work_keys_str_mv |
AT mennickentsigrid simplifiedliquidliquidextractionmethodcoupledwithlcdadbyquantitativedeterminationofrisperidoneinhumanserum AT diegomartade simplifiedliquidliquidextractionmethodcoupledwithlcdadbyquantitativedeterminationofrisperidoneinhumanserum AT liserbernd simplifiedliquidliquidextractionmethodcoupledwithlcdadbyquantitativedeterminationofrisperidoneinhumanserum AT trujillolina simplifiedliquidliquidextractionmethodcoupledwithlcdadbyquantitativedeterminationofrisperidoneinhumanserum |
_version_ |
1714200933268717568 |