SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM

ABSTRACT Risperidone, an antipsychotic drug, was determined in human serum, using an optimized liquid-liquid extraction for isolation from biological fluid, with ethyl acetate as extraction solvent. This sample extraction method was chosen to increase extraction efficiency and reduce matrix interfer...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mennickent,Sigrid, Diego,Marta De, Liser,Bernd, Trujillo,Lina
Lenguaje:English
Publicado: Sociedad Chilena de Química 2019
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072019000104265
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0717-97072019000104265
record_format dspace
spelling oai:scielo:S0717-970720190001042652019-04-11SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUMMennickent,SigridDiego,Marta DeLiser,BerndTrujillo,Lina Risperidone human serum liquid chromatography quantitative determination ABSTRACT Risperidone, an antipsychotic drug, was determined in human serum, using an optimized liquid-liquid extraction for isolation from biological fluid, with ethyl acetate as extraction solvent. This sample extraction method was chosen to increase extraction efficiency and reduce matrix interferences. Quantitation was achieved by LC/DAD at 294 nm over the concentration range of 1 ng/mL to 60 ng/mL (r=0.999). Desipramine was used as internal standard (tR for Risperidone: 4.23; tR Desipramine: 7.31). Mobile phase was water: acetonitrile: triethilamine: glacial acetic acid (70:29.16:0.52: 0.33 v/v), using a Purosphere STAR RP-18e 250 × 4.5 mm (5µ) column. RSD, for the intra-assay study, was between 0.52 % – 2.09 % (n=3), and between 0.79 % −3.25 % (n=9) for the inter-assay. LOD was 0.40 ng/mL and LOQ was 0.87 ng/mL. Recovery percentage for the accuracy study was between 90.82% and 98.56% ((RSD ≤ 3.93). The method is simple, fast, precise, accurate, sensible and selective. This method was successfully applied to quantify risperidone in patient serum samples. In conclusion, the method is useful for quantitative determination of risperidone in human serum.info:eu-repo/semantics/openAccessSociedad Chilena de QuímicaJournal of the Chilean Chemical Society v.64 n.1 20192019-03-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072019000104265en10.4067/s0717-97072019000104265
institution Scielo Chile
collection Scielo Chile
language English
topic Risperidone
human serum
liquid chromatography
quantitative determination
spellingShingle Risperidone
human serum
liquid chromatography
quantitative determination
Mennickent,Sigrid
Diego,Marta De
Liser,Bernd
Trujillo,Lina
SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM
description ABSTRACT Risperidone, an antipsychotic drug, was determined in human serum, using an optimized liquid-liquid extraction for isolation from biological fluid, with ethyl acetate as extraction solvent. This sample extraction method was chosen to increase extraction efficiency and reduce matrix interferences. Quantitation was achieved by LC/DAD at 294 nm over the concentration range of 1 ng/mL to 60 ng/mL (r=0.999). Desipramine was used as internal standard (tR for Risperidone: 4.23; tR Desipramine: 7.31). Mobile phase was water: acetonitrile: triethilamine: glacial acetic acid (70:29.16:0.52: 0.33 v/v), using a Purosphere STAR RP-18e 250 × 4.5 mm (5µ) column. RSD, for the intra-assay study, was between 0.52 % – 2.09 % (n=3), and between 0.79 % −3.25 % (n=9) for the inter-assay. LOD was 0.40 ng/mL and LOQ was 0.87 ng/mL. Recovery percentage for the accuracy study was between 90.82% and 98.56% ((RSD ≤ 3.93). The method is simple, fast, precise, accurate, sensible and selective. This method was successfully applied to quantify risperidone in patient serum samples. In conclusion, the method is useful for quantitative determination of risperidone in human serum.
author Mennickent,Sigrid
Diego,Marta De
Liser,Bernd
Trujillo,Lina
author_facet Mennickent,Sigrid
Diego,Marta De
Liser,Bernd
Trujillo,Lina
author_sort Mennickent,Sigrid
title SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM
title_short SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM
title_full SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM
title_fullStr SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM
title_full_unstemmed SIMPLIFIED LIQUID-LIQUID EXTRACTION METHOD COUPLED WITH LC/DAD BY QUANTITATIVE DETERMINATION OF RISPERIDONE IN HUMAN SERUM
title_sort simplified liquid-liquid extraction method coupled with lc/dad by quantitative determination of risperidone in human serum
publisher Sociedad Chilena de Química
publishDate 2019
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072019000104265
work_keys_str_mv AT mennickentsigrid simplifiedliquidliquidextractionmethodcoupledwithlcdadbyquantitativedeterminationofrisperidoneinhumanserum
AT diegomartade simplifiedliquidliquidextractionmethodcoupledwithlcdadbyquantitativedeterminationofrisperidoneinhumanserum
AT liserbernd simplifiedliquidliquidextractionmethodcoupledwithlcdadbyquantitativedeterminationofrisperidoneinhumanserum
AT trujillolina simplifiedliquidliquidextractionmethodcoupledwithlcdadbyquantitativedeterminationofrisperidoneinhumanserum
_version_ 1714200933268717568