ELECTROMAGNETIC COMPATIBILITY OF A DC POWER DISTRIBUTION SYSTEM FOR THE ATLAS LIQUID ARGON CALORIMETER
The front-end electronics of the ATLAS Liquid Argon Calorimeter is powered by DC/DC converters nearby the front-end crates. They are fed by AC/DC converters located in a remote control room through long power cables. The stability of the power distribution scheme is compromised by the impedance of t...
Guardado en:
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | English |
Publicado: |
Universidad de Tarapacá.
2008
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052008000100015 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0718-33052008000100015 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0718-330520080001000152009-03-06ELECTROMAGNETIC COMPATIBILITY OF A DC POWER DISTRIBUTION SYSTEM FOR THE ATLAS LIQUID ARGON CALORIMETERBlanchot,GeorgeHervas,LuisKierstead,JimLanni,FrancescoRescia,SergioVerdugo,MauricioPontt,JorgeOlivares,RicardoRobles,HernánDíaz,Sergio Electromagnetic compatibility DC power distribution system stability noise propagation EMI emissions The front-end electronics of the ATLAS Liquid Argon Calorimeter is powered by DC/DC converters nearby the front-end crates. They are fed by AC/DC converters located in a remote control room through long power cables. The stability of the power distribution scheme is compromised by the impedance of the long interconnection cable, and proper matching of the converters dynamic impedances is required. Also, the long power cable fed by a powerful AC/DC converter is a source of electromagnetic interferences in the experimental area. The optimal grounding and shielding configuration to minimize these EMI is discussed.info:eu-repo/semantics/openAccessUniversidad de Tarapacá.Ingeniare. Revista chilena de ingeniería v.16 n.1 20082008-06-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052008000100015en10.4067/S0718-33052008000100015 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Electromagnetic compatibility DC power distribution system stability noise propagation EMI emissions |
spellingShingle |
Electromagnetic compatibility DC power distribution system stability noise propagation EMI emissions Blanchot,George Hervas,Luis Kierstead,Jim Lanni,Francesco Rescia,Sergio Verdugo,Mauricio Pontt,Jorge Olivares,Ricardo Robles,Hernán Díaz,Sergio ELECTROMAGNETIC COMPATIBILITY OF A DC POWER DISTRIBUTION SYSTEM FOR THE ATLAS LIQUID ARGON CALORIMETER |
description |
The front-end electronics of the ATLAS Liquid Argon Calorimeter is powered by DC/DC converters nearby the front-end crates. They are fed by AC/DC converters located in a remote control room through long power cables. The stability of the power distribution scheme is compromised by the impedance of the long interconnection cable, and proper matching of the converters dynamic impedances is required. Also, the long power cable fed by a powerful AC/DC converter is a source of electromagnetic interferences in the experimental area. The optimal grounding and shielding configuration to minimize these EMI is discussed. |
author |
Blanchot,George Hervas,Luis Kierstead,Jim Lanni,Francesco Rescia,Sergio Verdugo,Mauricio Pontt,Jorge Olivares,Ricardo Robles,Hernán Díaz,Sergio |
author_facet |
Blanchot,George Hervas,Luis Kierstead,Jim Lanni,Francesco Rescia,Sergio Verdugo,Mauricio Pontt,Jorge Olivares,Ricardo Robles,Hernán Díaz,Sergio |
author_sort |
Blanchot,George |
title |
ELECTROMAGNETIC COMPATIBILITY OF A DC POWER DISTRIBUTION SYSTEM FOR THE ATLAS LIQUID ARGON CALORIMETER |
title_short |
ELECTROMAGNETIC COMPATIBILITY OF A DC POWER DISTRIBUTION SYSTEM FOR THE ATLAS LIQUID ARGON CALORIMETER |
title_full |
ELECTROMAGNETIC COMPATIBILITY OF A DC POWER DISTRIBUTION SYSTEM FOR THE ATLAS LIQUID ARGON CALORIMETER |
title_fullStr |
ELECTROMAGNETIC COMPATIBILITY OF A DC POWER DISTRIBUTION SYSTEM FOR THE ATLAS LIQUID ARGON CALORIMETER |
title_full_unstemmed |
ELECTROMAGNETIC COMPATIBILITY OF A DC POWER DISTRIBUTION SYSTEM FOR THE ATLAS LIQUID ARGON CALORIMETER |
title_sort |
electromagnetic compatibility of a dc power distribution system for the atlas liquid argon calorimeter |
publisher |
Universidad de Tarapacá. |
publishDate |
2008 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052008000100015 |
work_keys_str_mv |
AT blanchotgeorge electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter AT hervasluis electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter AT kiersteadjim electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter AT lannifrancesco electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter AT resciasergio electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter AT verdugomauricio electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter AT ponttjorge electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter AT olivaresricardo electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter AT robleshernan electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter AT diazsergio electromagneticcompatibilityofadcpowerdistributionsystemfortheatlasliquidargoncalorimeter |
_version_ |
1714203365839208448 |