Development of a scale prototype of isokinetic dynamometer

In recent decades, scientific advances in strength training and physical therapy enabled the development of machines, which can monitor and perform the exercise with versatility and multifunctionality, such as the isokinetic dynamometers (ID). Nowadays it can be identified some problems with ID, inc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ponce Saldías,Daniel Alejandro, Martins,Daniel, Martin,Carlos, Da Silva Rosa,Fabíola, de Mello Roesler,Carlos Rodrigo, Ocampo Moré,Ari Digiácomo
Lenguaje:English
Publicado: Universidad de Tarapacá. 2015
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052015000200005
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0718-33052015000200005
record_format dspace
spelling oai:scielo:S0718-330520150002000052015-04-01Development of a scale prototype of isokinetic dynamometerPonce Saldías,Daniel AlejandroMartins,DanielMartin,CarlosDa Silva Rosa,Fabíolade Mello Roesler,Carlos RodrigoOcampo Moré,Ari Digiácomo Isokinetic dynamometer physiotherapy control mechatronics product development In recent decades, scientific advances in strength training and physical therapy enabled the development of machines, which can monitor and perform the exercise with versatility and multifunctionality, such as the isokinetic dynamometers (ID). Nowadays it can be identified some problems with ID, including: a) high cost, b) isokinetic impact, c) posture on the dynamometer do not simulate the posture on sports, d) misalignment of the articular anatomic center of rotation to the center of rotation of the dynamometer. The objective of the present research is to develop a prototype of a new ID conception that should give theoretical and practical support to performing solutions that satisfy the problems related above. The prototype of a new ID conception is deployed by PRODIP methodology encompassing the phases of planning design, informational design, conceptual design and preliminary design. Comparing the simulated results with the theory, for each exercise mode, it can be concluded that the prototype can be used to support possible innovations for the problems mentioned above.info:eu-repo/semantics/openAccessUniversidad de Tarapacá.Ingeniare. Revista chilena de ingeniería v.23 n.2 20152015-04-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052015000200005en10.4067/S0718-33052015000200005
institution Scielo Chile
collection Scielo Chile
language English
topic Isokinetic dynamometer
physiotherapy
control
mechatronics
product development
spellingShingle Isokinetic dynamometer
physiotherapy
control
mechatronics
product development
Ponce Saldías,Daniel Alejandro
Martins,Daniel
Martin,Carlos
Da Silva Rosa,Fabíola
de Mello Roesler,Carlos Rodrigo
Ocampo Moré,Ari Digiácomo
Development of a scale prototype of isokinetic dynamometer
description In recent decades, scientific advances in strength training and physical therapy enabled the development of machines, which can monitor and perform the exercise with versatility and multifunctionality, such as the isokinetic dynamometers (ID). Nowadays it can be identified some problems with ID, including: a) high cost, b) isokinetic impact, c) posture on the dynamometer do not simulate the posture on sports, d) misalignment of the articular anatomic center of rotation to the center of rotation of the dynamometer. The objective of the present research is to develop a prototype of a new ID conception that should give theoretical and practical support to performing solutions that satisfy the problems related above. The prototype of a new ID conception is deployed by PRODIP methodology encompassing the phases of planning design, informational design, conceptual design and preliminary design. Comparing the simulated results with the theory, for each exercise mode, it can be concluded that the prototype can be used to support possible innovations for the problems mentioned above.
author Ponce Saldías,Daniel Alejandro
Martins,Daniel
Martin,Carlos
Da Silva Rosa,Fabíola
de Mello Roesler,Carlos Rodrigo
Ocampo Moré,Ari Digiácomo
author_facet Ponce Saldías,Daniel Alejandro
Martins,Daniel
Martin,Carlos
Da Silva Rosa,Fabíola
de Mello Roesler,Carlos Rodrigo
Ocampo Moré,Ari Digiácomo
author_sort Ponce Saldías,Daniel Alejandro
title Development of a scale prototype of isokinetic dynamometer
title_short Development of a scale prototype of isokinetic dynamometer
title_full Development of a scale prototype of isokinetic dynamometer
title_fullStr Development of a scale prototype of isokinetic dynamometer
title_full_unstemmed Development of a scale prototype of isokinetic dynamometer
title_sort development of a scale prototype of isokinetic dynamometer
publisher Universidad de Tarapacá.
publishDate 2015
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052015000200005
work_keys_str_mv AT poncesaldiasdanielalejandro developmentofascaleprototypeofisokineticdynamometer
AT martinsdaniel developmentofascaleprototypeofisokineticdynamometer
AT martincarlos developmentofascaleprototypeofisokineticdynamometer
AT dasilvarosafabiola developmentofascaleprototypeofisokineticdynamometer
AT demelloroeslercarlosrodrigo developmentofascaleprototypeofisokineticdynamometer
AT ocampomorearidigiacomo developmentofascaleprototypeofisokineticdynamometer
_version_ 1714203421725163520