Comparative analysis of semi-active control algorithms applied to magnetorheological dampers
ABSTRACT This paper analyzes the performance of three different semi-active control algorithms used to calculate and manage the optimal damping forces generated by a pair of magnetorheological (MR) dampers installed in a two-story building. The semi-active algorithms used are the linear quadratic re...
Guardado en:
Autores principales: | , , |
---|---|
Lenguaje: | English |
Publicado: |
Universidad de Tarapacá.
2017
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052017000100039 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0718-33052017000100039 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0718-330520170001000392017-03-10Comparative analysis of semi-active control algorithms applied to magnetorheological dampersLara-V.,Luis A.Brito,José L.V.Valencia G.,Yamile Structure dynamics semi-active control of structures vibration reduction magnetorheological dampers control algorithms intelligent systems ABSTRACT This paper analyzes the performance of three different semi-active control algorithms used to calculate and manage the optimal damping forces generated by a pair of magnetorheological (MR) dampers installed in a two-story building. The semi-active algorithms used are the linear quadratic regulator (LQR) associated with the clipped optimal algorithm, an algorithm based on a prediction model and a dynamic inverse model using nonlinear autoregressive exogenous (NARX)-type artificial neural networks, and a decision-making algorithm based on fuzzy logic. Additionally, the performances of the proposed semi-active algorithms are compared to those of passively used control devices. The results show response value reductions exceeding 50% for all the semi-active control strategies, which considerably outperformed the passive control. The three control strategies are thus confirmed as interesting tools with potential applications as MR damper administrators.info:eu-repo/semantics/openAccessUniversidad de Tarapacá.Ingeniare. Revista chilena de ingeniería v.25 n.1 20172017-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052017000100039en10.4067/S0718-33052017000100039 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Structure dynamics semi-active control of structures vibration reduction magnetorheological dampers control algorithms intelligent systems |
spellingShingle |
Structure dynamics semi-active control of structures vibration reduction magnetorheological dampers control algorithms intelligent systems Lara-V.,Luis A. Brito,José L.V. Valencia G.,Yamile Comparative analysis of semi-active control algorithms applied to magnetorheological dampers |
description |
ABSTRACT This paper analyzes the performance of three different semi-active control algorithms used to calculate and manage the optimal damping forces generated by a pair of magnetorheological (MR) dampers installed in a two-story building. The semi-active algorithms used are the linear quadratic regulator (LQR) associated with the clipped optimal algorithm, an algorithm based on a prediction model and a dynamic inverse model using nonlinear autoregressive exogenous (NARX)-type artificial neural networks, and a decision-making algorithm based on fuzzy logic. Additionally, the performances of the proposed semi-active algorithms are compared to those of passively used control devices. The results show response value reductions exceeding 50% for all the semi-active control strategies, which considerably outperformed the passive control. The three control strategies are thus confirmed as interesting tools with potential applications as MR damper administrators. |
author |
Lara-V.,Luis A. Brito,José L.V. Valencia G.,Yamile |
author_facet |
Lara-V.,Luis A. Brito,José L.V. Valencia G.,Yamile |
author_sort |
Lara-V.,Luis A. |
title |
Comparative analysis of semi-active control algorithms applied to magnetorheological dampers |
title_short |
Comparative analysis of semi-active control algorithms applied to magnetorheological dampers |
title_full |
Comparative analysis of semi-active control algorithms applied to magnetorheological dampers |
title_fullStr |
Comparative analysis of semi-active control algorithms applied to magnetorheological dampers |
title_full_unstemmed |
Comparative analysis of semi-active control algorithms applied to magnetorheological dampers |
title_sort |
comparative analysis of semi-active control algorithms applied to magnetorheological dampers |
publisher |
Universidad de Tarapacá. |
publishDate |
2017 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052017000100039 |
work_keys_str_mv |
AT laravluisa comparativeanalysisofsemiactivecontrolalgorithmsappliedtomagnetorheologicaldampers AT britojoselv comparativeanalysisofsemiactivecontrolalgorithmsappliedtomagnetorheologicaldampers AT valenciagyamile comparativeanalysisofsemiactivecontrolalgorithmsappliedtomagnetorheologicaldampers |
_version_ |
1714203442528911360 |