A comparative study of gravimetric and electrochemical techniques for the evaluation of corrosión inhibitor activity onset and efficiency in pipeline CO2 environments
ABSTRACT The monitoring of internal corrosion of pipelines is a critical element of the pipeline maintenance programs. A benchmarking study of enhanced techniques for real-time corrosion monitoring such as Linear Polarization Resistance and Harmonic Distortion Analysis was performed, enhanced Electr...
Guardado en:
Autores principales: | , , |
---|---|
Lenguaje: | English |
Publicado: |
Universidad de Tarapacá.
2019
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052019000400625 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0718-33052019000400625 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0718-330520190004006252020-01-29A comparative study of gravimetric and electrochemical techniques for the evaluation of corrosión inhibitor activity onset and efficiency in pipeline CO2 environmentsCáceres,A.Casales,M.Martínez,L. Internal corrosion real time corrosion monitoring corrosion inhibitors linear polarization resistance harmonic analysis electrical resistance coupons corrosion ABSTRACT The monitoring of internal corrosion of pipelines is a critical element of the pipeline maintenance programs. A benchmarking study of enhanced techniques for real-time corrosion monitoring such as Linear Polarization Resistance and Harmonic Distortion Analysis was performed, enhanced Electrical Resistance in conjunction with standard metal coupon. The transition of the corrosion processes occurring in metals immersed in corrosive electrolytes at the onset of inhibitor action after its injection was found a revealing item for study. This study considered a 3% NaCl solution with and without 10% diesel, saturated with CO2 at 50 °C and standard AISI 1018 coupons. A set of generic corrosion imidazoline-based inhibitors was studied. The benefits of employing real-time corrosion monitoring devices include shortened test times, increased number of inhibitors evaluated, and an increase in data quality and quantity. Results show that the corrosion rates from linear polarization resistance in the solution without inhibitor were overestimated, while the Harmonic Distortion Analysis and enhanced Electrical Resistance presented similar results to Standard Coupon. The enhanced electrical resistance monitoring also proved to be a good device to reveal the onset of corrosion protection after the inhibitor is applied.info:eu-repo/semantics/openAccessUniversidad de Tarapacá.Ingeniare. Revista chilena de ingeniería v.27 n.4 20192019-12-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052019000400625en10.4067/S0718-33052019000400625 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Internal corrosion real time corrosion monitoring corrosion inhibitors linear polarization resistance harmonic analysis electrical resistance coupons corrosion |
spellingShingle |
Internal corrosion real time corrosion monitoring corrosion inhibitors linear polarization resistance harmonic analysis electrical resistance coupons corrosion Cáceres,A. Casales,M. Martínez,L. A comparative study of gravimetric and electrochemical techniques for the evaluation of corrosión inhibitor activity onset and efficiency in pipeline CO2 environments |
description |
ABSTRACT The monitoring of internal corrosion of pipelines is a critical element of the pipeline maintenance programs. A benchmarking study of enhanced techniques for real-time corrosion monitoring such as Linear Polarization Resistance and Harmonic Distortion Analysis was performed, enhanced Electrical Resistance in conjunction with standard metal coupon. The transition of the corrosion processes occurring in metals immersed in corrosive electrolytes at the onset of inhibitor action after its injection was found a revealing item for study. This study considered a 3% NaCl solution with and without 10% diesel, saturated with CO2 at 50 °C and standard AISI 1018 coupons. A set of generic corrosion imidazoline-based inhibitors was studied. The benefits of employing real-time corrosion monitoring devices include shortened test times, increased number of inhibitors evaluated, and an increase in data quality and quantity. Results show that the corrosion rates from linear polarization resistance in the solution without inhibitor were overestimated, while the Harmonic Distortion Analysis and enhanced Electrical Resistance presented similar results to Standard Coupon. The enhanced electrical resistance monitoring also proved to be a good device to reveal the onset of corrosion protection after the inhibitor is applied. |
author |
Cáceres,A. Casales,M. Martínez,L. |
author_facet |
Cáceres,A. Casales,M. Martínez,L. |
author_sort |
Cáceres,A. |
title |
A comparative study of gravimetric and electrochemical techniques for the evaluation of corrosión inhibitor activity onset and efficiency in pipeline CO2 environments |
title_short |
A comparative study of gravimetric and electrochemical techniques for the evaluation of corrosión inhibitor activity onset and efficiency in pipeline CO2 environments |
title_full |
A comparative study of gravimetric and electrochemical techniques for the evaluation of corrosión inhibitor activity onset and efficiency in pipeline CO2 environments |
title_fullStr |
A comparative study of gravimetric and electrochemical techniques for the evaluation of corrosión inhibitor activity onset and efficiency in pipeline CO2 environments |
title_full_unstemmed |
A comparative study of gravimetric and electrochemical techniques for the evaluation of corrosión inhibitor activity onset and efficiency in pipeline CO2 environments |
title_sort |
comparative study of gravimetric and electrochemical techniques for the evaluation of corrosión inhibitor activity onset and efficiency in pipeline co2 environments |
publisher |
Universidad de Tarapacá. |
publishDate |
2019 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-33052019000400625 |
work_keys_str_mv |
AT caceresa acomparativestudyofgravimetricandelectrochemicaltechniquesfortheevaluationofcorrosioninhibitoractivityonsetandefficiencyinpipelineco2environments AT casalesm acomparativestudyofgravimetricandelectrochemicaltechniquesfortheevaluationofcorrosioninhibitoractivityonsetandefficiencyinpipelineco2environments AT martinezl acomparativestudyofgravimetricandelectrochemicaltechniquesfortheevaluationofcorrosioninhibitoractivityonsetandefficiencyinpipelineco2environments AT caceresa comparativestudyofgravimetricandelectrochemicaltechniquesfortheevaluationofcorrosioninhibitoractivityonsetandefficiencyinpipelineco2environments AT casalesm comparativestudyofgravimetricandelectrochemicaltechniquesfortheevaluationofcorrosioninhibitoractivityonsetandefficiencyinpipelineco2environments AT martinezl comparativestudyofgravimetricandelectrochemicaltechniquesfortheevaluationofcorrosioninhibitoractivityonsetandefficiencyinpipelineco2environments |
_version_ |
1714203474839732224 |