Insertion Torque of Mini Dental Implants and their Failure Risk after Immediate Loading

A minimum insertion torque has been suggested for immediate function of regular diameter implants. Even when there is a growing tendency to use Mini Dental Implants (MDIs) for immediate function of dentures, there is no clinical data concerning MDIs insertion torque, nor its influence on implant fai...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Jofre,J, Conrady,Y, Lagos-Álvarez,B
Lenguaje:English
Publicado: Universidad de La Frontera. Facultad de Medicina 2014
Materias:
jaw
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2014000300006
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0718-381X2014000300006
record_format dspace
spelling oai:scielo:S0718-381X20140003000062015-01-29Insertion Torque of Mini Dental Implants and their Failure Risk after Immediate LoadingJofre,JConrady,YLagos-Álvarez,B mini dental implant insertion torque denture overlay mini implant failure jaw edentulous A minimum insertion torque has been suggested for immediate function of regular diameter implants. Even when there is a growing tendency to use Mini Dental Implants (MDIs) for immediate function of dentures, there is no clinical data concerning MDIs insertion torque, nor its influence on implant failure. The aim of this prospective study was to assess the insertion torque of immediate loaded MDIs in edentulous patients and its association with risk failure. Ninety MDIs were placed in the anterior mandible of 45 edentulous patients, two per patient. The insertion torque was recorded with an electronic device and failures were documented during two years follow-up. All implants were immediately loaded with overdentures, using ball (44/90) or bar (46/90) attachments. A Kaplan­Meier survival probability estimator and a fitted multiple Cox regression model were performed to establish the influence of insertion torque and other clinical parameters on implant risk failure. The average insertion torque of 90 MDIs was 12.5±7.8 Ncm. A cumulative survival rate of 94.2% (5/90) was found by means of the Kaplan-Meier estimation. The Cox proportional-hazards regression model showed no association between insertion torque and MDIs failure. MDIs have much lower insertion torque than average conventional implants. The insertion torque of MDIs immediately loaded with mandibular dentures, seems not to be a risk factor associated to failure, at two years follow-up.info:eu-repo/semantics/openAccessUniversidad de La Frontera. Facultad de MedicinaInternational journal of odontostomatology v.8 n.3 20142014-12-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2014000300006en10.4067/S0718-381X2014000300006
institution Scielo Chile
collection Scielo Chile
language English
topic mini dental implant
insertion torque
denture
overlay
mini implant failure
jaw
edentulous
spellingShingle mini dental implant
insertion torque
denture
overlay
mini implant failure
jaw
edentulous
Jofre,J
Conrady,Y
Lagos-Álvarez,B
Insertion Torque of Mini Dental Implants and their Failure Risk after Immediate Loading
description A minimum insertion torque has been suggested for immediate function of regular diameter implants. Even when there is a growing tendency to use Mini Dental Implants (MDIs) for immediate function of dentures, there is no clinical data concerning MDIs insertion torque, nor its influence on implant failure. The aim of this prospective study was to assess the insertion torque of immediate loaded MDIs in edentulous patients and its association with risk failure. Ninety MDIs were placed in the anterior mandible of 45 edentulous patients, two per patient. The insertion torque was recorded with an electronic device and failures were documented during two years follow-up. All implants were immediately loaded with overdentures, using ball (44/90) or bar (46/90) attachments. A Kaplan­Meier survival probability estimator and a fitted multiple Cox regression model were performed to establish the influence of insertion torque and other clinical parameters on implant risk failure. The average insertion torque of 90 MDIs was 12.5±7.8 Ncm. A cumulative survival rate of 94.2% (5/90) was found by means of the Kaplan-Meier estimation. The Cox proportional-hazards regression model showed no association between insertion torque and MDIs failure. MDIs have much lower insertion torque than average conventional implants. The insertion torque of MDIs immediately loaded with mandibular dentures, seems not to be a risk factor associated to failure, at two years follow-up.
author Jofre,J
Conrady,Y
Lagos-Álvarez,B
author_facet Jofre,J
Conrady,Y
Lagos-Álvarez,B
author_sort Jofre,J
title Insertion Torque of Mini Dental Implants and their Failure Risk after Immediate Loading
title_short Insertion Torque of Mini Dental Implants and their Failure Risk after Immediate Loading
title_full Insertion Torque of Mini Dental Implants and their Failure Risk after Immediate Loading
title_fullStr Insertion Torque of Mini Dental Implants and their Failure Risk after Immediate Loading
title_full_unstemmed Insertion Torque of Mini Dental Implants and their Failure Risk after Immediate Loading
title_sort insertion torque of mini dental implants and their failure risk after immediate loading
publisher Universidad de La Frontera. Facultad de Medicina
publishDate 2014
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2014000300006
work_keys_str_mv AT jofrej insertiontorqueofminidentalimplantsandtheirfailureriskafterimmediateloading
AT conradyy insertiontorqueofminidentalimplantsandtheirfailureriskafterimmediateloading
AT lagosalvarezb insertiontorqueofminidentalimplantsandtheirfailureriskafterimmediateloading
_version_ 1714203959301767168