Accuracy of Resonance Frequency Analysis by Third Generation Osstell®
The Resonance Frequency Analysis by Osstell® is used in the assessment of primary and secondary implant stability. The aim of this study was to determine its accuracy as a method of testing, checking its repeatability and reproducibility. A pilot study was performed whereby implants were placed in a...
Guardado en:
| Autores principales: | , , , , |
|---|---|
| Lenguaje: | English |
| Publicado: |
Universidad de La Frontera. Facultad de Medicina
2015
|
| Materias: | |
| Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2015000300021 |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| id |
oai:scielo:S0718-381X2015000300021 |
|---|---|
| record_format |
dspace |
| spelling |
oai:scielo:S0718-381X20150003000212016-03-22Accuracy of Resonance Frequency Analysis by Third Generation Osstell®Brizuela-Velasco,AritzaFernández-González,Felipe JMartín-Blanco,NereaChávarri-Prado,DavidChento-Valiente,Yelko Osstell resonance frequency analysis implant stability repeatability and reproducibility The Resonance Frequency Analysis by Osstell® is used in the assessment of primary and secondary implant stability. The aim of this study was to determine its accuracy as a method of testing, checking its repeatability and reproducibility. A pilot study was performed whereby implants were placed in a cow rib to compare several ISQ measurements with the same SmartPeg transducer (repeatability), or with different SmartPegs (reproducibility). Statistical analysis of the data showed a high correlation of the ISQ values obtained in both assays, which suggests that Osstell®analysis can provide high repeatability and reproducibility.info:eu-repo/semantics/openAccessUniversidad de La Frontera. Facultad de MedicinaInternational journal of odontostomatology v.9 n.3 20152015-12-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2015000300021en10.4067/S0718-381X2015000300021 |
| institution |
Scielo Chile |
| collection |
Scielo Chile |
| language |
English |
| topic |
Osstell resonance frequency analysis implant stability repeatability and reproducibility |
| spellingShingle |
Osstell resonance frequency analysis implant stability repeatability and reproducibility Brizuela-Velasco,Aritza Fernández-González,Felipe J Martín-Blanco,Nerea Chávarri-Prado,David Chento-Valiente,Yelko Accuracy of Resonance Frequency Analysis by Third Generation Osstell® |
| description |
The Resonance Frequency Analysis by Osstell® is used in the assessment of primary and secondary implant stability. The aim of this study was to determine its accuracy as a method of testing, checking its repeatability and reproducibility. A pilot study was performed whereby implants were placed in a cow rib to compare several ISQ measurements with the same SmartPeg transducer (repeatability), or with different SmartPegs (reproducibility). Statistical analysis of the data showed a high correlation of the ISQ values obtained in both assays, which suggests that Osstell®analysis can provide high repeatability and reproducibility. |
| author |
Brizuela-Velasco,Aritza Fernández-González,Felipe J Martín-Blanco,Nerea Chávarri-Prado,David Chento-Valiente,Yelko |
| author_facet |
Brizuela-Velasco,Aritza Fernández-González,Felipe J Martín-Blanco,Nerea Chávarri-Prado,David Chento-Valiente,Yelko |
| author_sort |
Brizuela-Velasco,Aritza |
| title |
Accuracy of Resonance Frequency Analysis by Third Generation Osstell® |
| title_short |
Accuracy of Resonance Frequency Analysis by Third Generation Osstell® |
| title_full |
Accuracy of Resonance Frequency Analysis by Third Generation Osstell® |
| title_fullStr |
Accuracy of Resonance Frequency Analysis by Third Generation Osstell® |
| title_full_unstemmed |
Accuracy of Resonance Frequency Analysis by Third Generation Osstell® |
| title_sort |
accuracy of resonance frequency analysis by third generation osstell® |
| publisher |
Universidad de La Frontera. Facultad de Medicina |
| publishDate |
2015 |
| url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2015000300021 |
| work_keys_str_mv |
AT brizuelavelascoaritza accuracyofresonancefrequencyanalysisbythirdgenerationosstell AT fernandezgonzalezfelipej accuracyofresonancefrequencyanalysisbythirdgenerationosstell AT martinblanconerea accuracyofresonancefrequencyanalysisbythirdgenerationosstell AT chavarripradodavid accuracyofresonancefrequencyanalysisbythirdgenerationosstell AT chentovalienteyelko accuracyofresonancefrequencyanalysisbythirdgenerationosstell |
| _version_ |
1714203973751144448 |