Microhardness and Diametral Compression Strength of Single Fill Composite

ABSTRACT: To evaluate Knoop microhardness and diametral compression strength at different polymerization times. A total of 80 cylindrical samples with Filtek resin™ One Bulk Fill were made to perform the in vitro study, using half of total samples (n=40) for each test and divided equally b...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: de-Jesus,Ricardo Huver, Lage,Kalenna Soriano, Dalboni,Valéria Chiabai, Delboni,Ornella Luisa, Matos,Jefferson David Melo de, Nakano,Leonardo Jiro Nomura, Ortiz,Laura Patricia Nadal, Vasconcelos,John Eversong Lucena de, Bottino,Marco Antonio, Maciel,Lucas Campagnaro
Lenguaje:English
Publicado: Universidad de La Frontera. Facultad de Medicina 2021
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000100293
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0718-381X2021000100293
record_format dspace
spelling oai:scielo:S0718-381X20210001002932021-02-16Microhardness and Diametral Compression Strength of Single Fill Compositede-Jesus,Ricardo HuverLage,Kalenna SorianoDalboni,Valéria ChiabaiDelboni,Ornella LuisaMatos,Jefferson David Melo deNakano,Leonardo Jiro NomuraOrtiz,Laura Patricia NadalVasconcelos,John Eversong Lucena deBottino,Marco AntonioMaciel,Lucas Campagnaro composite resins hardness stress, mechanical physical properties ABSTRACT: To evaluate Knoop microhardness and diametral compression strength at different polymerization times. A total of 80 cylindrical samples with Filtek resin™ One Bulk Fill were made to perform the in vitro study, using half of total samples (n=40) for each test and divided equally between groups (n=10). All samples were made according to ISO 4049 using 2 mm thickness Teflon matrix and a central orifice with 4 mm diameter. Four different times of light-curing in Standard mode suggested by the light-unit manufacturer were selected, therefore, group 1 samples (G1) were light-cured for 5 seconds; group 2 (G2) for 10 seconds; group 3 (G3) for 15 seconds, and group 4 (G4) for 20 seconds. A radiant display, which means a power in mW/cm2 by time in seconds was expressed in Joules (J). The samples were stored in a dark container with distilled water at a temperature of 37°C for 48 hours before testing. One-way analysis of variance (ANOVA) with T-Test (LSD) of multiple comparisons of the mean values of Knoop hardness and diametral compression strength was performed, with significance index α=0.05. Regarding the Knoop microhardness test, G1 (35.73 ± 6.2) presented the lowest values, followed by G2, while G3 and G4 did not present statistical differences between them. For the diametral compression test, G1 (1387.76 ± 190.51) obtained the lowest value when compared to the other groups. G2, G3, and G4 did not present significant statistical differences. The different polymerization times influenced the Knoop microhardness and the diametral compression strength of Bulk Fill resin.info:eu-repo/semantics/openAccessUniversidad de La Frontera. Facultad de MedicinaInternational journal of odontostomatology v.15 n.1 20212021-03-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000100293en10.4067/S0718-381X2021000100293
institution Scielo Chile
collection Scielo Chile
language English
topic composite resins
hardness
stress, mechanical
physical properties
spellingShingle composite resins
hardness
stress, mechanical
physical properties
de-Jesus,Ricardo Huver
Lage,Kalenna Soriano
Dalboni,Valéria Chiabai
Delboni,Ornella Luisa
Matos,Jefferson David Melo de
Nakano,Leonardo Jiro Nomura
Ortiz,Laura Patricia Nadal
Vasconcelos,John Eversong Lucena de
Bottino,Marco Antonio
Maciel,Lucas Campagnaro
Microhardness and Diametral Compression Strength of Single Fill Composite
description ABSTRACT: To evaluate Knoop microhardness and diametral compression strength at different polymerization times. A total of 80 cylindrical samples with Filtek resin™ One Bulk Fill were made to perform the in vitro study, using half of total samples (n=40) for each test and divided equally between groups (n=10). All samples were made according to ISO 4049 using 2 mm thickness Teflon matrix and a central orifice with 4 mm diameter. Four different times of light-curing in Standard mode suggested by the light-unit manufacturer were selected, therefore, group 1 samples (G1) were light-cured for 5 seconds; group 2 (G2) for 10 seconds; group 3 (G3) for 15 seconds, and group 4 (G4) for 20 seconds. A radiant display, which means a power in mW/cm2 by time in seconds was expressed in Joules (J). The samples were stored in a dark container with distilled water at a temperature of 37°C for 48 hours before testing. One-way analysis of variance (ANOVA) with T-Test (LSD) of multiple comparisons of the mean values of Knoop hardness and diametral compression strength was performed, with significance index α=0.05. Regarding the Knoop microhardness test, G1 (35.73 ± 6.2) presented the lowest values, followed by G2, while G3 and G4 did not present statistical differences between them. For the diametral compression test, G1 (1387.76 ± 190.51) obtained the lowest value when compared to the other groups. G2, G3, and G4 did not present significant statistical differences. The different polymerization times influenced the Knoop microhardness and the diametral compression strength of Bulk Fill resin.
author de-Jesus,Ricardo Huver
Lage,Kalenna Soriano
Dalboni,Valéria Chiabai
Delboni,Ornella Luisa
Matos,Jefferson David Melo de
Nakano,Leonardo Jiro Nomura
Ortiz,Laura Patricia Nadal
Vasconcelos,John Eversong Lucena de
Bottino,Marco Antonio
Maciel,Lucas Campagnaro
author_facet de-Jesus,Ricardo Huver
Lage,Kalenna Soriano
Dalboni,Valéria Chiabai
Delboni,Ornella Luisa
Matos,Jefferson David Melo de
Nakano,Leonardo Jiro Nomura
Ortiz,Laura Patricia Nadal
Vasconcelos,John Eversong Lucena de
Bottino,Marco Antonio
Maciel,Lucas Campagnaro
author_sort de-Jesus,Ricardo Huver
title Microhardness and Diametral Compression Strength of Single Fill Composite
title_short Microhardness and Diametral Compression Strength of Single Fill Composite
title_full Microhardness and Diametral Compression Strength of Single Fill Composite
title_fullStr Microhardness and Diametral Compression Strength of Single Fill Composite
title_full_unstemmed Microhardness and Diametral Compression Strength of Single Fill Composite
title_sort microhardness and diametral compression strength of single fill composite
publisher Universidad de La Frontera. Facultad de Medicina
publishDate 2021
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000100293
work_keys_str_mv AT dejesusricardohuver microhardnessanddiametralcompressionstrengthofsinglefillcomposite
AT lagekalennasoriano microhardnessanddiametralcompressionstrengthofsinglefillcomposite
AT dalbonivaleriachiabai microhardnessanddiametralcompressionstrengthofsinglefillcomposite
AT delboniornellaluisa microhardnessanddiametralcompressionstrengthofsinglefillcomposite
AT matosjeffersondavidmelode microhardnessanddiametralcompressionstrengthofsinglefillcomposite
AT nakanoleonardojironomura microhardnessanddiametralcompressionstrengthofsinglefillcomposite
AT ortizlaurapatricianadal microhardnessanddiametralcompressionstrengthofsinglefillcomposite
AT vasconcelosjohneversonglucenade microhardnessanddiametralcompressionstrengthofsinglefillcomposite
AT bottinomarcoantonio microhardnessanddiametralcompressionstrengthofsinglefillcomposite
AT maciellucascampagnaro microhardnessanddiametralcompressionstrengthofsinglefillcomposite
_version_ 1714204049988911104