Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants
ABSTRACT: This study aimed to evaluate possible changes in final retention after nine sequences of insertion and removal (SIR) of a frictional Morse taper implant/abutment system, evaluating the force required for dissociating this set between sequences, and verifying possible deformations in the im...
Guardado en:
Autores principales: | , , , , , |
---|---|
Lenguaje: | English |
Publicado: |
Universidad de La Frontera. Facultad de Medicina
2021
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000200356 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0718-381X2021000200356 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0718-381X20210002003562021-06-08Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implantsda-Silva,Jader MoreiraSobral,Brenda SantosCabral,Carolina TakisSouza,Cíntia de Melo SilvaFonseca,Ricardo Roberto de SouzaRamacciato,Juliana Cama Tensile strength Dental implant Friction Dental Implant-Abutment Design Dentistry ABSTRACT: This study aimed to evaluate possible changes in final retention after nine sequences of insertion and removal (SIR) of a frictional Morse taper implant/abutment system, evaluating the force required for dissociating this set between sequences, and verifying possible deformations in the implant heads. Ten implants, 13 mm long and 3.3 mm in diameter, were coupled to a universal mechanical testing machine. Ten anti-rotational abutments, 13 mm long and 3.5 mm in diameter, were connected to the implants parallel to the long axis, using an instrument called beat-connection, and subjected to tensile tests and SEM analysis. The results were analyzed using the Kruskal-Wallis test with Dunn’s post-test, and the significance level was set at 5 %. There was no statistically significant difference in final retention among the nine SIRs evaluated. The force needed to uncouple the abutment from the implant increased as SIRs were performed on all ten implants, and an increase of 29.03 % was observed in the ninth SIR compared to the first SIR. After SEM analysis, no significant deformations, fractures, or cracks were observed in the implant heads.info:eu-repo/semantics/openAccessUniversidad de La Frontera. Facultad de MedicinaInternational journal of odontostomatology v.15 n.2 20212021-06-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000200356en10.4067/S0718-381X2021000200356 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Tensile strength Dental implant Friction Dental Implant-Abutment Design Dentistry |
spellingShingle |
Tensile strength Dental implant Friction Dental Implant-Abutment Design Dentistry da-Silva,Jader Moreira Sobral,Brenda Santos Cabral,Carolina Takis Souza,Cíntia de Melo Silva Fonseca,Ricardo Roberto de Souza Ramacciato,Juliana Cama Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants |
description |
ABSTRACT: This study aimed to evaluate possible changes in final retention after nine sequences of insertion and removal (SIR) of a frictional Morse taper implant/abutment system, evaluating the force required for dissociating this set between sequences, and verifying possible deformations in the implant heads. Ten implants, 13 mm long and 3.3 mm in diameter, were coupled to a universal mechanical testing machine. Ten anti-rotational abutments, 13 mm long and 3.5 mm in diameter, were connected to the implants parallel to the long axis, using an instrument called beat-connection, and subjected to tensile tests and SEM analysis. The results were analyzed using the Kruskal-Wallis test with Dunn’s post-test, and the significance level was set at 5 %. There was no statistically significant difference in final retention among the nine SIRs evaluated. The force needed to uncouple the abutment from the implant increased as SIRs were performed on all ten implants, and an increase of 29.03 % was observed in the ninth SIR compared to the first SIR. After SEM analysis, no significant deformations, fractures, or cracks were observed in the implant heads. |
author |
da-Silva,Jader Moreira Sobral,Brenda Santos Cabral,Carolina Takis Souza,Cíntia de Melo Silva Fonseca,Ricardo Roberto de Souza Ramacciato,Juliana Cama |
author_facet |
da-Silva,Jader Moreira Sobral,Brenda Santos Cabral,Carolina Takis Souza,Cíntia de Melo Silva Fonseca,Ricardo Roberto de Souza Ramacciato,Juliana Cama |
author_sort |
da-Silva,Jader Moreira |
title |
Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants |
title_short |
Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants |
title_full |
Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants |
title_fullStr |
Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants |
title_full_unstemmed |
Evaluation of tensile strength after insertions andremovals of abutments on frictional Morse taper implants |
title_sort |
evaluation of tensile strength after insertions andremovals of abutments on frictional morse taper implants |
publisher |
Universidad de La Frontera. Facultad de Medicina |
publishDate |
2021 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000200356 |
work_keys_str_mv |
AT dasilvajadermoreira evaluationoftensilestrengthafterinsertionsandremovalsofabutmentsonfrictionalmorsetaperimplants AT sobralbrendasantos evaluationoftensilestrengthafterinsertionsandremovalsofabutmentsonfrictionalmorsetaperimplants AT cabralcarolinatakis evaluationoftensilestrengthafterinsertionsandremovalsofabutmentsonfrictionalmorsetaperimplants AT souzacintiademelosilva evaluationoftensilestrengthafterinsertionsandremovalsofabutmentsonfrictionalmorsetaperimplants AT fonsecaricardorobertodesouza evaluationoftensilestrengthafterinsertionsandremovalsofabutmentsonfrictionalmorsetaperimplants AT ramacciatojulianacama evaluationoftensilestrengthafterinsertionsandremovalsofabutmentsonfrictionalmorsetaperimplants |
_version_ |
1714204051959185408 |