Dimensional Accuracy Comparison of Physical Models Generated by Digital Impression/3D-Printing or Analog Impression/Plaster Methods

ABSTRACT: This study aimed to compare the trueness and precision of physical models manufactured chairside (intraoral scanner and 3D printed) or by plaster models obtained using impression with alginate or addition silicone. A full- arch stainless steel die was impressed to obtain ten physical model...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Arcas,Luciana Paula Benicio, Tribst,João Paulo Mendes, Baroudi,Kusai, Amaral,Marina, Silva-Concílio,Lais Regiane da, Vitti,Rafael Pino
Lenguaje:English
Publicado: Universidad de La Frontera. Facultad de Medicina 2021
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000300562
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0718-381X2021000300562
record_format dspace
spelling oai:scielo:S0718-381X20210003005622021-09-21Dimensional Accuracy Comparison of Physical Models Generated by Digital Impression/3D-Printing or Analog Impression/Plaster MethodsArcas,Luciana Paula BenicioTribst,João Paulo MendesBaroudi,KusaiAmaral,MarinaSilva-Concílio,Lais Regiane daVitti,Rafael Pino three-dimensional printing dimensional measurement accuracy data accuracy dental models ABSTRACT: This study aimed to compare the trueness and precision of physical models manufactured chairside (intraoral scanner and 3D printed) or by plaster models obtained using impression with alginate or addition silicone. A full- arch stainless steel die was impressed to obtain ten physical models for each group. The models were measured in a stereomicroscope, considering four linear distances. To assess the precision accuracy, an analysis of the measurement variability was carried out, identified by the coefficients of variation and by the Levene&#8217;s test to compare the groups. To analyze trueness, the data average was subtracted from the database and compared considering alpha as 5 %. Considering precision, the higher dispersion of data occurred in the models obtained with silicone impression. And for trueness, Kruskal Wallis and Dunn tests results did not indicate differences between the groups in the anteroposterior linear distances (p> 0.05). Only in anterior transverse distance obtained through TRIOS (0.31 mm), it presented lower accuracy compared to the models from silicone impression (0.13 mm); however, at transverse posterior distance, the models from silicone impression showed the lowest accuracy (p <0.05). There was no difference between the models from scanning (p> 0.05). The physical dental models obtained by digital and analog workflows showed acceptable dimensional accuracy expressed by high precision and trueness. There is no difference between the evaluated intraoral scanner systems and the impression materials for the full-arch impression.info:eu-repo/semantics/openAccessUniversidad de La Frontera. Facultad de MedicinaInternational journal of odontostomatology v.15 n.3 20212021-09-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000300562en10.4067/S0718-381X2021000300562
institution Scielo Chile
collection Scielo Chile
language English
topic three-dimensional printing
dimensional measurement accuracy
data accuracy
dental models
spellingShingle three-dimensional printing
dimensional measurement accuracy
data accuracy
dental models
Arcas,Luciana Paula Benicio
Tribst,João Paulo Mendes
Baroudi,Kusai
Amaral,Marina
Silva-Concílio,Lais Regiane da
Vitti,Rafael Pino
Dimensional Accuracy Comparison of Physical Models Generated by Digital Impression/3D-Printing or Analog Impression/Plaster Methods
description ABSTRACT: This study aimed to compare the trueness and precision of physical models manufactured chairside (intraoral scanner and 3D printed) or by plaster models obtained using impression with alginate or addition silicone. A full- arch stainless steel die was impressed to obtain ten physical models for each group. The models were measured in a stereomicroscope, considering four linear distances. To assess the precision accuracy, an analysis of the measurement variability was carried out, identified by the coefficients of variation and by the Levene&#8217;s test to compare the groups. To analyze trueness, the data average was subtracted from the database and compared considering alpha as 5 %. Considering precision, the higher dispersion of data occurred in the models obtained with silicone impression. And for trueness, Kruskal Wallis and Dunn tests results did not indicate differences between the groups in the anteroposterior linear distances (p> 0.05). Only in anterior transverse distance obtained through TRIOS (0.31 mm), it presented lower accuracy compared to the models from silicone impression (0.13 mm); however, at transverse posterior distance, the models from silicone impression showed the lowest accuracy (p <0.05). There was no difference between the models from scanning (p> 0.05). The physical dental models obtained by digital and analog workflows showed acceptable dimensional accuracy expressed by high precision and trueness. There is no difference between the evaluated intraoral scanner systems and the impression materials for the full-arch impression.
author Arcas,Luciana Paula Benicio
Tribst,João Paulo Mendes
Baroudi,Kusai
Amaral,Marina
Silva-Concílio,Lais Regiane da
Vitti,Rafael Pino
author_facet Arcas,Luciana Paula Benicio
Tribst,João Paulo Mendes
Baroudi,Kusai
Amaral,Marina
Silva-Concílio,Lais Regiane da
Vitti,Rafael Pino
author_sort Arcas,Luciana Paula Benicio
title Dimensional Accuracy Comparison of Physical Models Generated by Digital Impression/3D-Printing or Analog Impression/Plaster Methods
title_short Dimensional Accuracy Comparison of Physical Models Generated by Digital Impression/3D-Printing or Analog Impression/Plaster Methods
title_full Dimensional Accuracy Comparison of Physical Models Generated by Digital Impression/3D-Printing or Analog Impression/Plaster Methods
title_fullStr Dimensional Accuracy Comparison of Physical Models Generated by Digital Impression/3D-Printing or Analog Impression/Plaster Methods
title_full_unstemmed Dimensional Accuracy Comparison of Physical Models Generated by Digital Impression/3D-Printing or Analog Impression/Plaster Methods
title_sort dimensional accuracy comparison of physical models generated by digital impression/3d-printing or analog impression/plaster methods
publisher Universidad de La Frontera. Facultad de Medicina
publishDate 2021
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000300562
work_keys_str_mv AT arcaslucianapaulabenicio dimensionalaccuracycomparisonofphysicalmodelsgeneratedbydigitalimpression3dprintingoranalogimpressionplastermethods
AT tribstjoaopaulomendes dimensionalaccuracycomparisonofphysicalmodelsgeneratedbydigitalimpression3dprintingoranalogimpressionplastermethods
AT baroudikusai dimensionalaccuracycomparisonofphysicalmodelsgeneratedbydigitalimpression3dprintingoranalogimpressionplastermethods
AT amaralmarina dimensionalaccuracycomparisonofphysicalmodelsgeneratedbydigitalimpression3dprintingoranalogimpressionplastermethods
AT silvaconciliolaisregianeda dimensionalaccuracycomparisonofphysicalmodelsgeneratedbydigitalimpression3dprintingoranalogimpressionplastermethods
AT vittirafaelpino dimensionalaccuracycomparisonofphysicalmodelsgeneratedbydigitalimpression3dprintingoranalogimpressionplastermethods
_version_ 1718324133757976576