Can the Incorporation of a Lead Foil on the Backside of Digital Receptors Produce a Better Endodontic Diagnosis?

ABSTRACT: This study evaluated influence of addition of lead foil coupled to different types of digital receptors on image noise and on diagnosis of fractured instruments in teeth without and with root filling. Twenty-six molars had their root canals (n=67) cleaned and shaped and were divided into g...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Costa,Eliana Dantas, Brasil,Danieli Moura, Gaêta-Araujo,Hugo, Brito,Ana Caroline Ramos, Oliveira-Santos,Christiano, Freitas,Deborah Queiroz
Lenguaje:English
Publicado: Universidad de La Frontera. Facultad de Medicina 2021
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000300734
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0718-381X2021000300734
record_format dspace
spelling oai:scielo:S0718-381X20210003007342021-09-21Can the Incorporation of a Lead Foil on the Backside of Digital Receptors Produce a Better Endodontic Diagnosis?Costa,Eliana DantasBrasil,Danieli MouraGaêta-Araujo,HugoBrito,Ana Caroline RamosOliveira-Santos,ChristianoFreitas,Deborah Queiroz endodontics instrumentation dentistry radiography ABSTRACT: This study evaluated influence of addition of lead foil coupled to different types of digital receptors on image noise and on diagnosis of fractured instruments in teeth without and with root filling. Twenty-six molars had their root canals (n=67) cleaned and shaped and were divided into groups with and without root filling and with and without fractured instruments. Images were acquired in PSP and CMOS sensor, with and without addition of a lead foil coupled to the digital receptors. Diagnostic values were obtained by the area under the ROC curve, and one-way ANOVA compared the groups. Noise in images was measured by the standard deviation of mean gray values in images with and without the lead foil, and compared by two-way ANOVA (a=0.05). Addition of lead foil did not interfere in the diagnostic accuracy for both digital systems (p>0.05) and did not decrease noise in the images (p>0.05). However, independently of the addition of the lead foil, the phosphor-storage plate presented higher noise compared to the sensor (p ?0.05). Addition of lead foil to the digital receptor did not interfere in image noise and with the diagnostic accuracy for detecting fracured endodontic instrument in ex-vivo conditions.info:eu-repo/semantics/openAccessUniversidad de La Frontera. Facultad de MedicinaInternational journal of odontostomatology v.15 n.3 20212021-09-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000300734en10.4067/S0718-381X2021000300734
institution Scielo Chile
collection Scielo Chile
language English
topic endodontics
instrumentation
dentistry
radiography
spellingShingle endodontics
instrumentation
dentistry
radiography
Costa,Eliana Dantas
Brasil,Danieli Moura
Gaêta-Araujo,Hugo
Brito,Ana Caroline Ramos
Oliveira-Santos,Christiano
Freitas,Deborah Queiroz
Can the Incorporation of a Lead Foil on the Backside of Digital Receptors Produce a Better Endodontic Diagnosis?
description ABSTRACT: This study evaluated influence of addition of lead foil coupled to different types of digital receptors on image noise and on diagnosis of fractured instruments in teeth without and with root filling. Twenty-six molars had their root canals (n=67) cleaned and shaped and were divided into groups with and without root filling and with and without fractured instruments. Images were acquired in PSP and CMOS sensor, with and without addition of a lead foil coupled to the digital receptors. Diagnostic values were obtained by the area under the ROC curve, and one-way ANOVA compared the groups. Noise in images was measured by the standard deviation of mean gray values in images with and without the lead foil, and compared by two-way ANOVA (a=0.05). Addition of lead foil did not interfere in the diagnostic accuracy for both digital systems (p>0.05) and did not decrease noise in the images (p>0.05). However, independently of the addition of the lead foil, the phosphor-storage plate presented higher noise compared to the sensor (p ?0.05). Addition of lead foil to the digital receptor did not interfere in image noise and with the diagnostic accuracy for detecting fracured endodontic instrument in ex-vivo conditions.
author Costa,Eliana Dantas
Brasil,Danieli Moura
Gaêta-Araujo,Hugo
Brito,Ana Caroline Ramos
Oliveira-Santos,Christiano
Freitas,Deborah Queiroz
author_facet Costa,Eliana Dantas
Brasil,Danieli Moura
Gaêta-Araujo,Hugo
Brito,Ana Caroline Ramos
Oliveira-Santos,Christiano
Freitas,Deborah Queiroz
author_sort Costa,Eliana Dantas
title Can the Incorporation of a Lead Foil on the Backside of Digital Receptors Produce a Better Endodontic Diagnosis?
title_short Can the Incorporation of a Lead Foil on the Backside of Digital Receptors Produce a Better Endodontic Diagnosis?
title_full Can the Incorporation of a Lead Foil on the Backside of Digital Receptors Produce a Better Endodontic Diagnosis?
title_fullStr Can the Incorporation of a Lead Foil on the Backside of Digital Receptors Produce a Better Endodontic Diagnosis?
title_full_unstemmed Can the Incorporation of a Lead Foil on the Backside of Digital Receptors Produce a Better Endodontic Diagnosis?
title_sort can the incorporation of a lead foil on the backside of digital receptors produce a better endodontic diagnosis?
publisher Universidad de La Frontera. Facultad de Medicina
publishDate 2021
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-381X2021000300734
work_keys_str_mv AT costaelianadantas cantheincorporationofaleadfoilonthebacksideofdigitalreceptorsproduceabetterendodonticdiagnosis
AT brasildanielimoura cantheincorporationofaleadfoilonthebacksideofdigitalreceptorsproduceabetterendodonticdiagnosis
AT gaetaaraujohugo cantheincorporationofaleadfoilonthebacksideofdigitalreceptorsproduceabetterendodonticdiagnosis
AT britoanacarolineramos cantheincorporationofaleadfoilonthebacksideofdigitalreceptorsproduceabetterendodonticdiagnosis
AT oliveirasantoschristiano cantheincorporationofaleadfoilonthebacksideofdigitalreceptorsproduceabetterendodonticdiagnosis
AT freitasdeborahqueiroz cantheincorporationofaleadfoilonthebacksideofdigitalreceptorsproduceabetterendodonticdiagnosis
_version_ 1718324146674335744