Simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fire
Abstract: The importance of structural design under fire conditions, together with the uncertainty in the behavior and resistance of reinforced concrete structures with fiber-reinforced polymer bars (FRP) at high temperatures, reveal the need for more research along these lines. Although there are s...
Guardado en:
Autores principales: | , , , |
---|---|
Lenguaje: | English |
Publicado: |
Pontificia Universidad Católica de Chile. Departamento de Ingeniería y Gestión de la Construcción
2021
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-50732021000100097 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0718-50732021000100097 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0718-507320210001000972021-05-28Simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fireDiaz,I.Larrúa,L.Wainshtok,H.Mackchaser,M. Beam reinforced concrete shear fire fiber-reinforced polymer (FRP) Abstract: The importance of structural design under fire conditions, together with the uncertainty in the behavior and resistance of reinforced concrete structures with fiber-reinforced polymer bars (FRP) at high temperatures, reveal the need for more research along these lines. Although there are studies evaluating the flexural and shear strength of elements exposed to fire, there are no standards nor regulations specifying the procedures thereto. This work proposes methods to calculate shear strength in FRP-reinforced concrete beams, with rectangular cross-section, based on the degradation of the properties of the materials and/or the reduced concrete cross-section, as recommended by Diab (2014), Eurocode 2 (EN-1992-1-2, 2004) and Saafi (2002). In accordance with the thermal analysis executed with the Super Tempcalc software, these procedures were applied to 13 beams of different dimensions and reinforcements, subjected to standard fire of the ISO-834 standard on three sides, thereby obtaining the shear capacity degradation curves for each case. The results show that the EN-1992-1-2 (2004) allows to adequately predict the shear strength of RC beams with FRP under fire conditions.info:eu-repo/semantics/openAccessPontificia Universidad Católica de Chile. Departamento de Ingeniería y Gestión de la ConstrucciónRevista ingeniería de construcción v.36 n.1 20212021-04-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-50732021000100097en10.4067/S0718-50732021000100097 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Beam reinforced concrete shear fire fiber-reinforced polymer (FRP) |
spellingShingle |
Beam reinforced concrete shear fire fiber-reinforced polymer (FRP) Diaz,I. Larrúa,L. Wainshtok,H. Mackchaser,M. Simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fire |
description |
Abstract: The importance of structural design under fire conditions, together with the uncertainty in the behavior and resistance of reinforced concrete structures with fiber-reinforced polymer bars (FRP) at high temperatures, reveal the need for more research along these lines. Although there are studies evaluating the flexural and shear strength of elements exposed to fire, there are no standards nor regulations specifying the procedures thereto. This work proposes methods to calculate shear strength in FRP-reinforced concrete beams, with rectangular cross-section, based on the degradation of the properties of the materials and/or the reduced concrete cross-section, as recommended by Diab (2014), Eurocode 2 (EN-1992-1-2, 2004) and Saafi (2002). In accordance with the thermal analysis executed with the Super Tempcalc software, these procedures were applied to 13 beams of different dimensions and reinforcements, subjected to standard fire of the ISO-834 standard on three sides, thereby obtaining the shear capacity degradation curves for each case. The results show that the EN-1992-1-2 (2004) allows to adequately predict the shear strength of RC beams with FRP under fire conditions. |
author |
Diaz,I. Larrúa,L. Wainshtok,H. Mackchaser,M. |
author_facet |
Diaz,I. Larrúa,L. Wainshtok,H. Mackchaser,M. |
author_sort |
Diaz,I. |
title |
Simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fire |
title_short |
Simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fire |
title_full |
Simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fire |
title_fullStr |
Simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fire |
title_full_unstemmed |
Simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fire |
title_sort |
simplified methods to determine shear strength in reinforced concrete beams with fiber-reinforced polymers exposed to fire |
publisher |
Pontificia Universidad Católica de Chile. Departamento de Ingeniería y Gestión de la Construcción |
publishDate |
2021 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-50732021000100097 |
work_keys_str_mv |
AT diazi simplifiedmethodstodetermineshearstrengthinreinforcedconcretebeamswithfiberreinforcedpolymersexposedtofire AT larrual simplifiedmethodstodetermineshearstrengthinreinforcedconcretebeamswithfiberreinforcedpolymersexposedtofire AT wainshtokh simplifiedmethodstodetermineshearstrengthinreinforcedconcretebeamswithfiberreinforcedpolymersexposedtofire AT mackchaserm simplifiedmethodstodetermineshearstrengthinreinforcedconcretebeamswithfiberreinforcedpolymersexposedtofire |
_version_ |
1714204931476422656 |