Thermal performance of novel frame-integrated unitised curtain wall
Framing of unitized curtain walls is dimensioned to carry wind load without taking advantage of potential composite contribution of glass. Subsequently, it is unnecessarily deep, occupying valuable space, and protrudes to the inside, causing visual disruption. Moreover, it is generally made of high...
Guardado en:
Autores principales: | , , |
---|---|
Lenguaje: | English |
Publicado: |
Escuela de Construcción Civil, Pontificia Universidad Católica de Chile
2015
|
Materias: | |
Acceso en línea: | http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-915X2015000100003 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:scielo:S0718-915X2015000100003 |
---|---|
record_format |
dspace |
spelling |
oai:scielo:S0718-915X20150001000032015-05-08Thermal performance of novel frame-integrated unitised curtain wallCordero,BelarminoGarcía-Santos,AlfonsoOverend,Mauro Curtain wall frame thermal Framing of unitized curtain walls is dimensioned to carry wind load without taking advantage of potential composite contribution of glass. Subsequently, it is unnecessarily deep, occupying valuable space, and protrudes to the inside, causing visual disruption. Moreover, it is generally made of high thermal conductivity metal alloys, contributing to substantial thermal transmission at joints. An innovative frame-integrated unitised curtain wall has been developed that, compared to conventional systems, reduces structural depth significantly, allows an inside flush finish and reduces thermal transmission at joints. The idea is to adhesively bond a Glass Fibre Reinforced Polymer (GFRP) frame to the edge of the Insulated Glass Unit (IGU), thereby achieving low thermal transmittance and composite structural behaviour. The frame is to fit within the glazing cavity depth. This paper provides a description of the proposed system and assesses its thermal transmittance and risk of condensation through comparative analytical and numerical thermal analysis with a conventional system taken as reference.info:eu-repo/semantics/openAccessEscuela de Construcción Civil, Pontificia Universidad Católica de ChileRevista de la construcción v.14 n.1 20152015-04-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-915X2015000100003en10.4067/S0718-915X2015000100003 |
institution |
Scielo Chile |
collection |
Scielo Chile |
language |
English |
topic |
Curtain wall frame thermal |
spellingShingle |
Curtain wall frame thermal Cordero,Belarmino García-Santos,Alfonso Overend,Mauro Thermal performance of novel frame-integrated unitised curtain wall |
description |
Framing of unitized curtain walls is dimensioned to carry wind load without taking advantage of potential composite contribution of glass. Subsequently, it is unnecessarily deep, occupying valuable space, and protrudes to the inside, causing visual disruption. Moreover, it is generally made of high thermal conductivity metal alloys, contributing to substantial thermal transmission at joints. An innovative frame-integrated unitised curtain wall has been developed that, compared to conventional systems, reduces structural depth significantly, allows an inside flush finish and reduces thermal transmission at joints. The idea is to adhesively bond a Glass Fibre Reinforced Polymer (GFRP) frame to the edge of the Insulated Glass Unit (IGU), thereby achieving low thermal transmittance and composite structural behaviour. The frame is to fit within the glazing cavity depth. This paper provides a description of the proposed system and assesses its thermal transmittance and risk of condensation through comparative analytical and numerical thermal analysis with a conventional system taken as reference. |
author |
Cordero,Belarmino García-Santos,Alfonso Overend,Mauro |
author_facet |
Cordero,Belarmino García-Santos,Alfonso Overend,Mauro |
author_sort |
Cordero,Belarmino |
title |
Thermal performance of novel frame-integrated unitised curtain wall |
title_short |
Thermal performance of novel frame-integrated unitised curtain wall |
title_full |
Thermal performance of novel frame-integrated unitised curtain wall |
title_fullStr |
Thermal performance of novel frame-integrated unitised curtain wall |
title_full_unstemmed |
Thermal performance of novel frame-integrated unitised curtain wall |
title_sort |
thermal performance of novel frame-integrated unitised curtain wall |
publisher |
Escuela de Construcción Civil, Pontificia Universidad Católica de Chile |
publishDate |
2015 |
url |
http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-915X2015000100003 |
work_keys_str_mv |
AT corderobelarmino thermalperformanceofnovelframeintegratedunitisedcurtainwall AT garciasantosalfonso thermalperformanceofnovelframeintegratedunitisedcurtainwall AT overendmauro thermalperformanceofnovelframeintegratedunitisedcurtainwall |
_version_ |
1714206269752999936 |