Design and construction recommendations for connections arrangement in anchored veneers with continuous air cavity

Abstract The optimization of connections arrangement to guarantee the anchored veneers with continuous air cavity stability is necessary, for better performance and durability of the façade. In this paper, different arrangements for the anchors to structure and different kinds of inner leaf are prop...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Mas,Ángeles, Vercher,Jose, Cubel,Francisco, Gil,Enrique, Lerma,Carlos
Lenguaje:English
Publicado: Escuela de Construcción Civil, Pontificia Universidad Católica de Chile 2018
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-915X2018000100137
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:scielo:S0718-915X2018000100137
record_format dspace
spelling oai:scielo:S0718-915X20180001001372018-08-22Design and construction recommendations for connections arrangement in anchored veneers with continuous air cavityMas,ÁngelesVercher,JoseCubel,FranciscoGil,EnriqueLerma,Carlos brickwork masonry wall ties self-supporting wall restraint connections Abstract The optimization of connections arrangement to guarantee the anchored veneers with continuous air cavity stability is necessary, for better performance and durability of the façade. In this paper, different arrangements for the anchors to structure and different kinds of inner leaf are proposed, with the aim of selecting the best for the behavior of the façade against wind actions in cases of residential buildings. A very significant increase in stiffness is observed simply placing the anchors to the structure alternately to one side and the other of the structural element, and it is still more when there are wall ties between leaves, especially to a brickwork inner leaf.info:eu-repo/semantics/openAccessEscuela de Construcción Civil, Pontificia Universidad Católica de ChileRevista de la construcción v.17 n.1 20182018-04-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-915X2018000100137en10.7764/rdlc.17.1.137
institution Scielo Chile
collection Scielo Chile
language English
topic brickwork
masonry
wall ties
self-supporting wall
restraint connections
spellingShingle brickwork
masonry
wall ties
self-supporting wall
restraint connections
Mas,Ángeles
Vercher,Jose
Cubel,Francisco
Gil,Enrique
Lerma,Carlos
Design and construction recommendations for connections arrangement in anchored veneers with continuous air cavity
description Abstract The optimization of connections arrangement to guarantee the anchored veneers with continuous air cavity stability is necessary, for better performance and durability of the façade. In this paper, different arrangements for the anchors to structure and different kinds of inner leaf are proposed, with the aim of selecting the best for the behavior of the façade against wind actions in cases of residential buildings. A very significant increase in stiffness is observed simply placing the anchors to the structure alternately to one side and the other of the structural element, and it is still more when there are wall ties between leaves, especially to a brickwork inner leaf.
author Mas,Ángeles
Vercher,Jose
Cubel,Francisco
Gil,Enrique
Lerma,Carlos
author_facet Mas,Ángeles
Vercher,Jose
Cubel,Francisco
Gil,Enrique
Lerma,Carlos
author_sort Mas,Ángeles
title Design and construction recommendations for connections arrangement in anchored veneers with continuous air cavity
title_short Design and construction recommendations for connections arrangement in anchored veneers with continuous air cavity
title_full Design and construction recommendations for connections arrangement in anchored veneers with continuous air cavity
title_fullStr Design and construction recommendations for connections arrangement in anchored veneers with continuous air cavity
title_full_unstemmed Design and construction recommendations for connections arrangement in anchored veneers with continuous air cavity
title_sort design and construction recommendations for connections arrangement in anchored veneers with continuous air cavity
publisher Escuela de Construcción Civil, Pontificia Universidad Católica de Chile
publishDate 2018
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0718-915X2018000100137
work_keys_str_mv AT masangeles designandconstructionrecommendationsforconnectionsarrangementinanchoredveneerswithcontinuousaircavity
AT vercherjose designandconstructionrecommendationsforconnectionsarrangementinanchoredveneerswithcontinuousaircavity
AT cubelfrancisco designandconstructionrecommendationsforconnectionsarrangementinanchoredveneerswithcontinuousaircavity
AT gilenrique designandconstructionrecommendationsforconnectionsarrangementinanchoredveneerswithcontinuousaircavity
AT lermacarlos designandconstructionrecommendationsforconnectionsarrangementinanchoredveneerswithcontinuousaircavity
_version_ 1714206289736761344