REDUCTION OF MATRIX EFFECTS IN PESTICIDE RESIDUE ANALYSIS IN FOOD BY PROGRAMMABLE TEMPERATURE VAPORIZER
Background: The phenomenon known as the ''matrix-induced chromatographic response enhancement'' commonly affects the sensibility, precision, and accuracy in pesticide residue analysis. The presence of matrix effects can be given by adsorption and/or thermal decomposition of pesti...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Universidad de Antioquia
2013
|
Materias: | |
Acceso en línea: | https://doaj.org/article/48f4d3f4cf074036897c6a6a86377e10 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:48f4d3f4cf074036897c6a6a86377e10 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:48f4d3f4cf074036897c6a6a86377e102021-12-02T10:53:38ZREDUCTION OF MATRIX EFFECTS IN PESTICIDE RESIDUE ANALYSIS IN FOOD BY PROGRAMMABLE TEMPERATURE VAPORIZER0121-4004https://doaj.org/article/48f4d3f4cf074036897c6a6a86377e102013-12-01T00:00:00Zhttp://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0121-40042013000300004&lng=en&tlng=enhttps://doaj.org/toc/0121-4004Background: The phenomenon known as the ''matrix-induced chromatographic response enhancement'' commonly affects the sensibility, precision, and accuracy in pesticide residue analysis. The presence of matrix effects can be given by adsorption and/or thermal decomposition of pesticides on the gas chromatograph injection port. Objective: To reduce the matrix-induced chromatographic response enhancement on pesticide residues analysis in food through the use of several operational modes of programmable temperature vaporizer inlet. Methods: The analyses were carried out in potato (Solanum tuberosum) extracts by gas chromatography with mass spectrometry detector. In this study, four programmable temperature vaporizer splitless modes were investigated: hot, pulsed, cold and solvent vent. Another topic developed in this study has to do with the influence of injection volume, assessed for the matrix effects. Results: The analysis of variance (ANOVA) (α = 0.05) indicates that when the hot splitless is used most compounds are subjected to matrix-induced chromatographic response enhancement. Furthermore, with the pulsed splitless, a decrease in the number of compounds with matrix-induced chromatographic response enhancement was found, approximately 20% compared to the classic hot splitless. Finally, a remarkable decrease in matrix-induced effects was found when cold splitless mode was used, since there was up to 55% reduction in the compounds, relative to traditional hot splitless, that showed statistical differences between responses in matrix-free standards and matrix-matched standards. Conclusions: It was found that the use of conventional hot splitless and pulsed splitless modes caused matrix-induced effects in more than 70% of the studied compounds. In addition, the results indicate that for most compounds there is an inverse relationship between matrix-induced chromatographic response enhancement and the volume of injection.D.A AHUMADAJ.A. GUERREROUniversidad de AntioquiaarticlePesticidesgas chromatographyfoodmass spectrometryresiduesPlaguicidascromatografía de gasesalimentosespectrometría de masasresiduosFood processing and manufactureTP368-456Pharmaceutical industryHD9665-9675ENVitae, Vol 20, Iss 3, Pp 184-194 (2013) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Pesticides gas chromatography food mass spectrometry residues Plaguicidas cromatografía de gases alimentos espectrometría de masas residuos Food processing and manufacture TP368-456 Pharmaceutical industry HD9665-9675 |
spellingShingle |
Pesticides gas chromatography food mass spectrometry residues Plaguicidas cromatografía de gases alimentos espectrometría de masas residuos Food processing and manufacture TP368-456 Pharmaceutical industry HD9665-9675 D.A AHUMADA J.A. GUERRERO REDUCTION OF MATRIX EFFECTS IN PESTICIDE RESIDUE ANALYSIS IN FOOD BY PROGRAMMABLE TEMPERATURE VAPORIZER |
description |
Background: The phenomenon known as the ''matrix-induced chromatographic response enhancement'' commonly affects the sensibility, precision, and accuracy in pesticide residue analysis. The presence of matrix effects can be given by adsorption and/or thermal decomposition of pesticides on the gas chromatograph injection port. Objective: To reduce the matrix-induced chromatographic response enhancement on pesticide residues analysis in food through the use of several operational modes of programmable temperature vaporizer inlet. Methods: The analyses were carried out in potato (Solanum tuberosum) extracts by gas chromatography with mass spectrometry detector. In this study, four programmable temperature vaporizer splitless modes were investigated: hot, pulsed, cold and solvent vent. Another topic developed in this study has to do with the influence of injection volume, assessed for the matrix effects. Results: The analysis of variance (ANOVA) (α = 0.05) indicates that when the hot splitless is used most compounds are subjected to matrix-induced chromatographic response enhancement. Furthermore, with the pulsed splitless, a decrease in the number of compounds with matrix-induced chromatographic response enhancement was found, approximately 20% compared to the classic hot splitless. Finally, a remarkable decrease in matrix-induced effects was found when cold splitless mode was used, since there was up to 55% reduction in the compounds, relative to traditional hot splitless, that showed statistical differences between responses in matrix-free standards and matrix-matched standards. Conclusions: It was found that the use of conventional hot splitless and pulsed splitless modes caused matrix-induced effects in more than 70% of the studied compounds. In addition, the results indicate that for most compounds there is an inverse relationship between matrix-induced chromatographic response enhancement and the volume of injection. |
format |
article |
author |
D.A AHUMADA J.A. GUERRERO |
author_facet |
D.A AHUMADA J.A. GUERRERO |
author_sort |
D.A AHUMADA |
title |
REDUCTION OF MATRIX EFFECTS IN PESTICIDE RESIDUE ANALYSIS IN FOOD BY PROGRAMMABLE TEMPERATURE VAPORIZER |
title_short |
REDUCTION OF MATRIX EFFECTS IN PESTICIDE RESIDUE ANALYSIS IN FOOD BY PROGRAMMABLE TEMPERATURE VAPORIZER |
title_full |
REDUCTION OF MATRIX EFFECTS IN PESTICIDE RESIDUE ANALYSIS IN FOOD BY PROGRAMMABLE TEMPERATURE VAPORIZER |
title_fullStr |
REDUCTION OF MATRIX EFFECTS IN PESTICIDE RESIDUE ANALYSIS IN FOOD BY PROGRAMMABLE TEMPERATURE VAPORIZER |
title_full_unstemmed |
REDUCTION OF MATRIX EFFECTS IN PESTICIDE RESIDUE ANALYSIS IN FOOD BY PROGRAMMABLE TEMPERATURE VAPORIZER |
title_sort |
reduction of matrix effects in pesticide residue analysis in food by programmable temperature vaporizer |
publisher |
Universidad de Antioquia |
publishDate |
2013 |
url |
https://doaj.org/article/48f4d3f4cf074036897c6a6a86377e10 |
work_keys_str_mv |
AT daahumada reductionofmatrixeffectsinpesticideresidueanalysisinfoodbyprogrammabletemperaturevaporizer AT jaguerrero reductionofmatrixeffectsinpesticideresidueanalysisinfoodbyprogrammabletemperaturevaporizer |
_version_ |
1718396466327715840 |