Factors affecting in-stent restenosis after angioplasty with the Enterprise stent for intracranial atherosclerotic diseases

Abstract This study investigated factors affecting the safety and in-stent restenosis after intracranial stent angioplasty using the Enterprise stent for symptomatic intracranial atherosclerotic stenosis. Between January 2017 and March 2019, patients with intracranial atherosclerotic stenosis treate...