Adaptive Control of Ion Yield in Femtosecond Laser Post-ionization for Secondary Ion Mass Spectrometry

Abstract Secondary ion mass spectrometry is an excellent technique of analytical chemistry, where primary ions sputter a solid sample generating the secondary ions which are determined. Although the ion yield is inherently low, it can be enhanced by using a post-ionization of sputtered neutral speci...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Dusan Lorenc, Monika Jerigova, Monika Stupavska, Dusan Velic
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/839e5dea7a92408ea53176c22da618c1
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:839e5dea7a92408ea53176c22da618c1
record_format dspace
spelling oai:doaj.org-article:839e5dea7a92408ea53176c22da618c12021-12-02T12:30:12ZAdaptive Control of Ion Yield in Femtosecond Laser Post-ionization for Secondary Ion Mass Spectrometry10.1038/s41598-017-06562-92045-2322https://doaj.org/article/839e5dea7a92408ea53176c22da618c12017-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-06562-9https://doaj.org/toc/2045-2322Abstract Secondary ion mass spectrometry is an excellent technique of analytical chemistry, where primary ions sputter a solid sample generating the secondary ions which are determined. Although the ion yield is inherently low, it can be enhanced by using a post-ionization of sputtered neutral species. Our novel approach integrates this technique with a near infrared femtosecond laser post-ionization based on an adaptive control through a laser pulse shaper. The shaping of the laser pulse provides adaptive control to select a mass peak of interest and to enhance this peak intensity. Versatility is confirmed by optimizing the ion yield for different molecules (tryptophan, anthracene, polyethylene, and oxalic acid) with focus on parent ion enhancement, fragmentation process, sublimation effect, and excited secondary species. This proof-of-concept experiment provides not only a nonspecific increase of the overall ion yield, but also the selection of specific secondary species and the adaptive enhancement of their intensities on the order of 100, potentially simplifying data interpretation. Such tailored spectra might advance the (secondary ion) mass spectrometry to new capabilities.Dusan LorencMonika JerigovaMonika StupavskaDusan VelicNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-7 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Dusan Lorenc
Monika Jerigova
Monika Stupavska
Dusan Velic
Adaptive Control of Ion Yield in Femtosecond Laser Post-ionization for Secondary Ion Mass Spectrometry
description Abstract Secondary ion mass spectrometry is an excellent technique of analytical chemistry, where primary ions sputter a solid sample generating the secondary ions which are determined. Although the ion yield is inherently low, it can be enhanced by using a post-ionization of sputtered neutral species. Our novel approach integrates this technique with a near infrared femtosecond laser post-ionization based on an adaptive control through a laser pulse shaper. The shaping of the laser pulse provides adaptive control to select a mass peak of interest and to enhance this peak intensity. Versatility is confirmed by optimizing the ion yield for different molecules (tryptophan, anthracene, polyethylene, and oxalic acid) with focus on parent ion enhancement, fragmentation process, sublimation effect, and excited secondary species. This proof-of-concept experiment provides not only a nonspecific increase of the overall ion yield, but also the selection of specific secondary species and the adaptive enhancement of their intensities on the order of 100, potentially simplifying data interpretation. Such tailored spectra might advance the (secondary ion) mass spectrometry to new capabilities.
format article
author Dusan Lorenc
Monika Jerigova
Monika Stupavska
Dusan Velic
author_facet Dusan Lorenc
Monika Jerigova
Monika Stupavska
Dusan Velic
author_sort Dusan Lorenc
title Adaptive Control of Ion Yield in Femtosecond Laser Post-ionization for Secondary Ion Mass Spectrometry
title_short Adaptive Control of Ion Yield in Femtosecond Laser Post-ionization for Secondary Ion Mass Spectrometry
title_full Adaptive Control of Ion Yield in Femtosecond Laser Post-ionization for Secondary Ion Mass Spectrometry
title_fullStr Adaptive Control of Ion Yield in Femtosecond Laser Post-ionization for Secondary Ion Mass Spectrometry
title_full_unstemmed Adaptive Control of Ion Yield in Femtosecond Laser Post-ionization for Secondary Ion Mass Spectrometry
title_sort adaptive control of ion yield in femtosecond laser post-ionization for secondary ion mass spectrometry
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/839e5dea7a92408ea53176c22da618c1
work_keys_str_mv AT dusanlorenc adaptivecontrolofionyieldinfemtosecondlaserpostionizationforsecondaryionmassspectrometry
AT monikajerigova adaptivecontrolofionyieldinfemtosecondlaserpostionizationforsecondaryionmassspectrometry
AT monikastupavska adaptivecontrolofionyieldinfemtosecondlaserpostionizationforsecondaryionmassspectrometry
AT dusanvelic adaptivecontrolofionyieldinfemtosecondlaserpostionizationforsecondaryionmassspectrometry
_version_ 1718394407428816896