Seismic performance analysis of self-centering segment piers with mortise-tenon shear connectors based on cyclic pseudo-static test

In the past decades, more and more precast piers have been used in actual engineering, which brings convenience in construction and standardization of production. However, precast piers still have some shortcomings, such as shear slip between segments and poor energy dissipation. Thus, a self-center...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Yongjun Ni, Changshun Hao, Yanzhou Xu
Formato: article
Lenguaje:EN
Publicado: JVE International 2021
Materias:
Acceso en línea:https://doaj.org/article/9abf66f2585b4106b392064e875a5756