Prediction model for early graft failure after liver transplantation using aspartate aminotransferase, total bilirubin and coagulation factor

Abstract This study was designed to build models predicting early graft failure after liver transplantation. Cox regression model for predicting early graft failure after liver transplantation using post-transplantation aspartate aminotransferase, total bilirubin, and international normalized ratio...

Full description

Saved in:
Bibliographic Details
Main Authors: Jinsoo Rhu, Jong Man Kim, Kyunga Kim, Heejin Yoo, Gyu-Seong Choi, Jae-Won Joh
Format: article
Language:EN
Published: Nature Portfolio 2021
Subjects:
R
Q
Online Access:https://doaj.org/article/ca33fcedf3684d00b0ffa4012b88638f
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract This study was designed to build models predicting early graft failure after liver transplantation. Cox regression model for predicting early graft failure after liver transplantation using post-transplantation aspartate aminotransferase, total bilirubin, and international normalized ratio of prothrombin time was constructed based on data from both living donor (n = 1153) and deceased donor (n = 359) liver transplantation performed during 2004 to 2018. The model was compared with Model for Early Allograft Function Scoring (MEAF) and early allograft dysfunction (EAD) with their C-index and time-dependent area-under-curve (AUC). The C-index of the model for living donor (0.73, CI = 0.67–0.79) was significantly higher compared to those of both MEAF (0.69, P = 0.03) and EAD (0.66, P = 0.001) while C-index for deceased donor (0.74, CI = 0.65–0.83) was only significantly higher compared to C-index of EAD. (0.66, P = 0.002) Time-dependent AUC at 2 weeks of living donor (0.96, CI = 0.91–1.00) and deceased donor (0.98, CI = 0.96–1.00) were significantly higher compared to those of EAD. (both 0.83, P < 0.001 for living donor and deceased donor) Time-dependent AUC at 4 weeks of living donor (0.93, CI = 0.86–0.99) was significantly higher compared to those of both MEAF (0.87, P = 0.02) and EAD. (0.84, P = 0.02) Time-dependent AUC at 4 weeks of deceased donor (0.94, CI = 0.89–1.00) was significantly higher compared to both MEAF (0.82, P = 0.02) and EAD. (0.81, P < 0.001). The prediction model for early graft failure after liver transplantation showed high predictability and validity with higher predictability compared to traditional models for both living donor and deceased donor liver transplantation.