The paper presents some principles and results of numerical field calculation and the corresponding harmonic analysis of magnetic field in the active zone of a large turbogenerator under load conditions. In addition to the traditional coordinate function of the magnetic induction, its time functions...

Full description

Saved in:
Bibliographic Details
Main Authors: V.I. Milykh, N.V. Polyakova
Format: article
Language:EN
RU
UK
Published: National Technical University "Kharkiv Polytechnic Institute" 2013
Subjects:
Online Access:https://doaj.org/article/cd7d212171d2444b9efd0d2d9e6add77
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The paper presents some principles and results of numerical field calculation and the corresponding harmonic analysis of magnetic field in the active zone of a large turbogenerator under load conditions. In addition to the traditional coordinate function of the magnetic induction, its time functions are considered at fixed points and at rotating rotor linked points in the gap. The stator magnetic flux linkage functions are also examined. It is revealed that these magnetic induction functions, which are different from sine curves, fail to provide the basis for determining time functions of magnetic flux linkage and the stator winding EMF that are close to sine waves.