Development of a Chiral Capillary Electrophoresis Method for the Enantioseparation of Verapamil Using Cyclodextrins as Chiral Selectors and Experimental Design Optimization
Chirality is a property of asymmetry which determines the pharmacokinetic and pharmacological profiles of optically active pharmaceuticals. Verapamil (VER), a calcium channel blocker phenylalkylamine derivative used in the treatment of cardio-vascular diseases, is a chiral compound, marketed as a ra...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/df69a0c708d14f3b9fef2dc0f7f54a08 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:df69a0c708d14f3b9fef2dc0f7f54a08 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:df69a0c708d14f3b9fef2dc0f7f54a082021-11-25T19:07:25ZDevelopment of a Chiral Capillary Electrophoresis Method for the Enantioseparation of Verapamil Using Cyclodextrins as Chiral Selectors and Experimental Design Optimization10.3390/sym131121862073-8994https://doaj.org/article/df69a0c708d14f3b9fef2dc0f7f54a082021-11-01T00:00:00Zhttps://www.mdpi.com/2073-8994/13/11/2186https://doaj.org/toc/2073-8994Chirality is a property of asymmetry which determines the pharmacokinetic and pharmacological profiles of optically active pharmaceuticals. Verapamil (VER), a calcium channel blocker phenylalkylamine derivative used in the treatment of cardio-vascular diseases, is a chiral compound, marketed as a racemate, although differences between the pharmacokinetic and pharmacological attributes of the enantiomers have been reported. The aim of our study was to develop a new chiral separation method for VER enantiomers by capillary electrophoresis (CE) using cyclodextrins (CDs) as chiral selectors (CSs). After an initial screening, using different native and derivatized CDs, at four pH levels, heptakis 2,3,6-tri-O-methyl-β-CD (TM-β-CD), a neutral derivatized CD, was identified as the optimum CS. For method optimization, a preliminary univariate approach was applied to characterize the influence of analytical parameters on the separation followed by a Box–Behnken experimental design to establish the optimal separation conditions. Chiral separation of enantiomers was achieved with a resolution of 1.58 in approximately 4 min; the migration order was <i>R</i>-VER followed by <i>S</i>-VER. The method analytical performance was evaluated in terms of precision, linearity, accuracy, and robustness (applying a Plackett–Burnam experimental design). The developed method was applied for the determination of VER enantiomers in pharmaceuticals. Finally, a computer modelling of VER–CD complexes was used to describe host–guest chiral recognition.Melania Cârcu-DobrinGabriel HancuLajos Attila PappIbolya FülöpHajnal KelemenMDPI AGarticleverapamilchiral separationcapillary electrophoresiscyclodextrinexperimental designmolecular modellingMathematicsQA1-939ENSymmetry, Vol 13, Iss 2186, p 2186 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
verapamil chiral separation capillary electrophoresis cyclodextrin experimental design molecular modelling Mathematics QA1-939 |
spellingShingle |
verapamil chiral separation capillary electrophoresis cyclodextrin experimental design molecular modelling Mathematics QA1-939 Melania Cârcu-Dobrin Gabriel Hancu Lajos Attila Papp Ibolya Fülöp Hajnal Kelemen Development of a Chiral Capillary Electrophoresis Method for the Enantioseparation of Verapamil Using Cyclodextrins as Chiral Selectors and Experimental Design Optimization |
description |
Chirality is a property of asymmetry which determines the pharmacokinetic and pharmacological profiles of optically active pharmaceuticals. Verapamil (VER), a calcium channel blocker phenylalkylamine derivative used in the treatment of cardio-vascular diseases, is a chiral compound, marketed as a racemate, although differences between the pharmacokinetic and pharmacological attributes of the enantiomers have been reported. The aim of our study was to develop a new chiral separation method for VER enantiomers by capillary electrophoresis (CE) using cyclodextrins (CDs) as chiral selectors (CSs). After an initial screening, using different native and derivatized CDs, at four pH levels, heptakis 2,3,6-tri-O-methyl-β-CD (TM-β-CD), a neutral derivatized CD, was identified as the optimum CS. For method optimization, a preliminary univariate approach was applied to characterize the influence of analytical parameters on the separation followed by a Box–Behnken experimental design to establish the optimal separation conditions. Chiral separation of enantiomers was achieved with a resolution of 1.58 in approximately 4 min; the migration order was <i>R</i>-VER followed by <i>S</i>-VER. The method analytical performance was evaluated in terms of precision, linearity, accuracy, and robustness (applying a Plackett–Burnam experimental design). The developed method was applied for the determination of VER enantiomers in pharmaceuticals. Finally, a computer modelling of VER–CD complexes was used to describe host–guest chiral recognition. |
format |
article |
author |
Melania Cârcu-Dobrin Gabriel Hancu Lajos Attila Papp Ibolya Fülöp Hajnal Kelemen |
author_facet |
Melania Cârcu-Dobrin Gabriel Hancu Lajos Attila Papp Ibolya Fülöp Hajnal Kelemen |
author_sort |
Melania Cârcu-Dobrin |
title |
Development of a Chiral Capillary Electrophoresis Method for the Enantioseparation of Verapamil Using Cyclodextrins as Chiral Selectors and Experimental Design Optimization |
title_short |
Development of a Chiral Capillary Electrophoresis Method for the Enantioseparation of Verapamil Using Cyclodextrins as Chiral Selectors and Experimental Design Optimization |
title_full |
Development of a Chiral Capillary Electrophoresis Method for the Enantioseparation of Verapamil Using Cyclodextrins as Chiral Selectors and Experimental Design Optimization |
title_fullStr |
Development of a Chiral Capillary Electrophoresis Method for the Enantioseparation of Verapamil Using Cyclodextrins as Chiral Selectors and Experimental Design Optimization |
title_full_unstemmed |
Development of a Chiral Capillary Electrophoresis Method for the Enantioseparation of Verapamil Using Cyclodextrins as Chiral Selectors and Experimental Design Optimization |
title_sort |
development of a chiral capillary electrophoresis method for the enantioseparation of verapamil using cyclodextrins as chiral selectors and experimental design optimization |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/df69a0c708d14f3b9fef2dc0f7f54a08 |
work_keys_str_mv |
AT melaniacarcudobrin developmentofachiralcapillaryelectrophoresismethodfortheenantioseparationofverapamilusingcyclodextrinsaschiralselectorsandexperimentaldesignoptimization AT gabrielhancu developmentofachiralcapillaryelectrophoresismethodfortheenantioseparationofverapamilusingcyclodextrinsaschiralselectorsandexperimentaldesignoptimization AT lajosattilapapp developmentofachiralcapillaryelectrophoresismethodfortheenantioseparationofverapamilusingcyclodextrinsaschiralselectorsandexperimentaldesignoptimization AT ibolyafulop developmentofachiralcapillaryelectrophoresismethodfortheenantioseparationofverapamilusingcyclodextrinsaschiralselectorsandexperimentaldesignoptimization AT hajnalkelemen developmentofachiralcapillaryelectrophoresismethodfortheenantioseparationofverapamilusingcyclodextrinsaschiralselectorsandexperimentaldesignoptimization |
_version_ |
1718410310795132928 |