Reversed phase HPLC determination of zidovudine in rat plasma and its pharmacokinetics after a single intranasal dose administration

The development and validation of a simple and accurate method based on HPLC with ultraviolet detection for the quantification of zidovudine in rat plasma and its application to a pharmacokinetic study following a single intranasal dose zidovudine is described. Zidovudine was extracted from the plas...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: MAINARDES,RUBIANA M, PALMIRA D. GREMIÃO,MARIA
Lenguaje:English
Publicado: Sociedad de Biología de Chile 2009
Materias:
AZT
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0716-97602009000300010
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:The development and validation of a simple and accurate method based on HPLC with ultraviolet detection for the quantification of zidovudine in rat plasma and its application to a pharmacokinetic study following a single intranasal dose zidovudine is described. Zidovudine was extracted from the plasma using a single-step deproteinization. Chromatographic separation of zidovudine from interfering components was achieved with a C-18 reverse phase column, a mobile phase consisting of a mixture of sodium acetate buffer (55mM) with pH adjusted to 7.0 and acetonitrile (91:9 v/v) and UV detection set at 265 nm. The method was linear from 100 to 10000 ng.mL"¹ (r² > 0.9995), and zidovudine had a mean recovery from plasma of 92.8%. The coefficient of variation of inter-day and intra-day quality control samples was less than 15%. After a single intranasal dose of zidovudine administered to rats, pharmacokinetic parameters (AUC0 24, Cmax, t , t1/2) were determined. The proposed method was found to be simple, specific, accurate, and precise and could be applied to the quantitative analysis of clinical pharmacokinetic studies of zidovudine in rats.