BIOEQUIVALENCE OF NORFLOXACIN BY HPLC-UV METHOD

A simple, rapid and convenient high performance liquid chromatographic method has been developed for the determination and bioequivalence of norfloxacin intablets formulations by using ciprofloxacin as an internal standard. The chromatographic separation was achieved on a C18 column having an isocra...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: SHER,MUHAMMAD, AJAZ HUSSAIN,MUHAMMAD, MEHMOOD,MHAMMAD HAMMAD, HASSAN,MUHAMMAD NAEEMUL, BASHIR,SAJID
Lenguaje:English
Publicado: Sociedad Chilena de Química 2010
Materias:
Acceso en línea:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-97072010000200012
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
Descripción
Sumario:A simple, rapid and convenient high performance liquid chromatographic method has been developed for the determination and bioequivalence of norfloxacin intablets formulations by using ciprofloxacin as an internal standard. The chromatographic separation was achieved on a C18 column having an isocratic mixture of methanol, disodium hydrogen phosphate buffer and acetonitrile (30:30:40) at pH 3 adjusted with o-phosphoric acid. The eluents were detected at 280 nm and quantitation was achieved on the basis of peak height ratio of norflaoxacin and internal standard. Limit of detection of the method developed was 15 ng mL-1> with a linear range of 30 - 200 ng mL-1. After single oral dose (400 mg) of two formulations (Noroxin, MSD and Ecoflaxin, Technovision Pharmaceutical) of norfloxacin administered to healthy volunteers using a randomize 2x2 crossover design, pharmacokinetics parameters (AUC0-t, AUC0-∞, Cmax, t½ ) were derived from the plasma concentrations curves for both formulations. Pharmacokinetic analysis of the data showed that the two formulations were bioequivalent, while no adverse reactions to drug were observed. In addition, the method evolved has been found suitable for the routine quality control tests.