Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)

Abstract Anisotropic X-ray Dark-field Tomography (AXDT) is a new imaging technique for reconstructing the three-dimensional scattering profile within a sample using the dark-field signal measured in an X-ray grating interferometry setup. As in any tomographic measurement, the acquisition geometry pl...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Y. Sharma, F. Schaff, M. Wieczorek, F. Pfeiffer, T. Lasser
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/40d5c5b6519c434682994f854fa1112b
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:40d5c5b6519c434682994f854fa1112b
record_format dspace
spelling oai:doaj.org-article:40d5c5b6519c434682994f854fa1112b2021-12-02T11:40:58ZDesign of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)10.1038/s41598-017-03329-02045-2322https://doaj.org/article/40d5c5b6519c434682994f854fa1112b2017-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-03329-0https://doaj.org/toc/2045-2322Abstract Anisotropic X-ray Dark-field Tomography (AXDT) is a new imaging technique for reconstructing the three-dimensional scattering profile within a sample using the dark-field signal measured in an X-ray grating interferometry setup. As in any tomographic measurement, the acquisition geometry plays a key role in the accurate reconstruction of the scattering information. More- over, the anisotropic nature of the dark-field signal poses additional challenges for designing the acquisition protocols. In this work, we present an efficient approach to measure scattering orientations spread over the unit sphere and prove its efficacy using the knowledge from conventional tomography. In addition, we conclude (using analytical and experimental results) that placing the gratings such that the grating bars make an angle of 45 degrees with respect to the vertical direction is the optimal setup configuration for AXDT.Y. SharmaF. SchaffM. WieczorekF. PfeifferT. LasserNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-10 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Y. Sharma
F. Schaff
M. Wieczorek
F. Pfeiffer
T. Lasser
Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)
description Abstract Anisotropic X-ray Dark-field Tomography (AXDT) is a new imaging technique for reconstructing the three-dimensional scattering profile within a sample using the dark-field signal measured in an X-ray grating interferometry setup. As in any tomographic measurement, the acquisition geometry plays a key role in the accurate reconstruction of the scattering information. More- over, the anisotropic nature of the dark-field signal poses additional challenges for designing the acquisition protocols. In this work, we present an efficient approach to measure scattering orientations spread over the unit sphere and prove its efficacy using the knowledge from conventional tomography. In addition, we conclude (using analytical and experimental results) that placing the gratings such that the grating bars make an angle of 45 degrees with respect to the vertical direction is the optimal setup configuration for AXDT.
format article
author Y. Sharma
F. Schaff
M. Wieczorek
F. Pfeiffer
T. Lasser
author_facet Y. Sharma
F. Schaff
M. Wieczorek
F. Pfeiffer
T. Lasser
author_sort Y. Sharma
title Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)
title_short Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)
title_full Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)
title_fullStr Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)
title_full_unstemmed Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)
title_sort design of acquisition schemes and setup geometry for anisotropic x-ray dark-field tomography (axdt)
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/40d5c5b6519c434682994f854fa1112b
work_keys_str_mv AT ysharma designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt
AT fschaff designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt
AT mwieczorek designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt
AT fpfeiffer designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt
AT tlasser designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt
_version_ 1718395512542986240