Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)
Abstract Anisotropic X-ray Dark-field Tomography (AXDT) is a new imaging technique for reconstructing the three-dimensional scattering profile within a sample using the dark-field signal measured in an X-ray grating interferometry setup. As in any tomographic measurement, the acquisition geometry pl...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Nature Portfolio
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/40d5c5b6519c434682994f854fa1112b |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:40d5c5b6519c434682994f854fa1112b |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:40d5c5b6519c434682994f854fa1112b2021-12-02T11:40:58ZDesign of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT)10.1038/s41598-017-03329-02045-2322https://doaj.org/article/40d5c5b6519c434682994f854fa1112b2017-06-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-03329-0https://doaj.org/toc/2045-2322Abstract Anisotropic X-ray Dark-field Tomography (AXDT) is a new imaging technique for reconstructing the three-dimensional scattering profile within a sample using the dark-field signal measured in an X-ray grating interferometry setup. As in any tomographic measurement, the acquisition geometry plays a key role in the accurate reconstruction of the scattering information. More- over, the anisotropic nature of the dark-field signal poses additional challenges for designing the acquisition protocols. In this work, we present an efficient approach to measure scattering orientations spread over the unit sphere and prove its efficacy using the knowledge from conventional tomography. In addition, we conclude (using analytical and experimental results) that placing the gratings such that the grating bars make an angle of 45 degrees with respect to the vertical direction is the optimal setup configuration for AXDT.Y. SharmaF. SchaffM. WieczorekF. PfeifferT. LasserNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-10 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Medicine R Science Q |
spellingShingle |
Medicine R Science Q Y. Sharma F. Schaff M. Wieczorek F. Pfeiffer T. Lasser Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT) |
description |
Abstract Anisotropic X-ray Dark-field Tomography (AXDT) is a new imaging technique for reconstructing the three-dimensional scattering profile within a sample using the dark-field signal measured in an X-ray grating interferometry setup. As in any tomographic measurement, the acquisition geometry plays a key role in the accurate reconstruction of the scattering information. More- over, the anisotropic nature of the dark-field signal poses additional challenges for designing the acquisition protocols. In this work, we present an efficient approach to measure scattering orientations spread over the unit sphere and prove its efficacy using the knowledge from conventional tomography. In addition, we conclude (using analytical and experimental results) that placing the gratings such that the grating bars make an angle of 45 degrees with respect to the vertical direction is the optimal setup configuration for AXDT. |
format |
article |
author |
Y. Sharma F. Schaff M. Wieczorek F. Pfeiffer T. Lasser |
author_facet |
Y. Sharma F. Schaff M. Wieczorek F. Pfeiffer T. Lasser |
author_sort |
Y. Sharma |
title |
Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT) |
title_short |
Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT) |
title_full |
Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT) |
title_fullStr |
Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT) |
title_full_unstemmed |
Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT) |
title_sort |
design of acquisition schemes and setup geometry for anisotropic x-ray dark-field tomography (axdt) |
publisher |
Nature Portfolio |
publishDate |
2017 |
url |
https://doaj.org/article/40d5c5b6519c434682994f854fa1112b |
work_keys_str_mv |
AT ysharma designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt AT fschaff designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt AT mwieczorek designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt AT fpfeiffer designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt AT tlasser designofacquisitionschemesandsetupgeometryforanisotropicxraydarkfieldtomographyaxdt |
_version_ |
1718395512542986240 |